Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/134367
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Rodríguez de Rivera, Miriam | - |
dc.contributor.author | Rodríguez de Rivera, Pedro Jesús | - |
dc.date.accessioned | 2024-10-08T12:29:33Z | - |
dc.date.available | 2024-10-08T12:29:33Z | - |
dc.date.issued | 2024 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/134367 | - |
dc.description.abstract | We present an optimized version of the skin calorimeter for measuring localized skin thermal responses during physical activity. Enhancements include a new holding system, more sensitive thermopiles, and an upgraded spiked heat sink for improved efficiency. In addition, we used a new, improved calorimetric model that takes into account all the variables that influence the measurement process. Resolution in power measurement is 1 mW. Performance tests under air currents and movement disturbances showed that the device maintains high accuracy; the deviation produced by these significant disturbances is less than 5%. Human subject tests, both at rest and during exercise, confirmed its ability to accurately measure localized skin heat flux, heat capacity, and thermal resistance (less than 5% uncertainty). These findings highlight the calorimeter’s potential for applications in sports medicine and physiological studies. | - |
dc.language | eng | - |
dc.relation.ispartof | Sensors (Switzerland) | - |
dc.source | Sensors [EISSN 1424-8220], v. 24 (18), (Septiembre 2024) | - |
dc.subject | 221308 Técnicas de medida del calor | - |
dc.subject | 241109 Regulación de la temperatura humana | - |
dc.subject.other | Conduction calorimetry | - |
dc.subject.other | Direct calorimetry | - |
dc.subject.other | Skin calorimeter | - |
dc.subject.other | Skin heat flux | - |
dc.subject.other | Skin thermal properties | - |
dc.subject.other | Sports medicine sensors | - |
dc.title | New, optimized skin calorimeter version for measuring thermal responses of localized skin areas during physical activity | - |
dc.type | info:eu-repo/semantics/Article | - |
dc.type | Article | - |
dc.identifier.doi | 10.3390/s24185927 | - |
dc.identifier.scopus | 85205231039 | - |
dc.identifier.isi | 001323204600001 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | 0000-0002-6343-6683 | - |
dc.contributor.authorscopusid | 57202152954 | - |
dc.contributor.authorscopusid | 57200590110 | - |
dc.identifier.eissn | 1424-8220 | - |
dc.identifier.issue | 18 | - |
dc.relation.volume | 24 | - |
dc.investigacion | Ciencias | - |
dc.type2 | Artículo | - |
dc.contributor.daisngid | No ID | - |
dc.contributor.daisngid | No ID | - |
dc.description.numberofpages | 13 | - |
dc.utils.revision | Sí | - |
dc.contributor.wosstandard | WOS:de Rivera, MR | - |
dc.contributor.wosstandard | WOS:de Rivera, PJR | - |
dc.date.coverdate | Septiembre 2024 | - |
dc.identifier.ulpgc | Sí | - |
dc.contributor.buulpgc | BU-BAS | - |
dc.description.sjr | 0,786 | - |
dc.description.jcr | 3,847 | - |
dc.description.sjrq | Q1 | - |
dc.description.jcrq | Q1 | - |
dc.description.scie | SCIE | - |
dc.description.miaricds | 10,8 | - |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR Termofísica de Líquidos y Calorimetría | - |
crisitem.author.dept | Departamento de Física | - |
crisitem.author.orcid | 0000-0002-6343-6683 | - |
crisitem.author.parentorg | Departamento de Física | - |
crisitem.author.fullName | Rodríguez De Rivera Socorro, Pedro Jesús | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.