Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/133642
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.advisor | Hernández Castellano, Lorenzo Enrique | - |
dc.contributor.advisor | Gonzalez Cabrera, Marta | - |
dc.contributor.advisor | Perez Acosta, Pablo | - |
dc.contributor.author | Hernández Rivero, Víctor Jesús | - |
dc.date.accessioned | 2024-10-07T10:33:57Z | - |
dc.date.available | 2024-10-07T10:33:57Z | - |
dc.date.issued | 2024 | en_US |
dc.identifier.other | Gestión académica | |
dc.identifier.uri | http://hdl.handle.net/10553/133642 | - |
dc.description.abstract | Heart rate, respiratory rate, and body temperature are crucial indicators of animal health and welfare. Traditionally, heart and respiratory rates are often monitored with a stethoscope, while body temperature is measured rectally. These methods require handling the animals, which could potentially cause stress. Given the significance of these physiological parameters, this study aims to validate non-invasive techniques for measuring heart and respiratory rates with a human finger pulse oximeter and body temperature with an infrared thermometer. The study involved 40 Holstein Friesian cows at various lactation stages. The experiment was conducted in an alleyway using batches of 3-4 animals immediately after the morning milking. Heart and respiratory rates were measured using a stethoscope and a finger pulse oximeter, which were placed on both pigmented and non-pigmented teats, as well as on front and rear teats. Infrared temperatures of both front and rear teats were measured with an infrared thermometer, and rectal temperature was recorded with a digital thermometer. The Pearson correlation coefficient was determined using the PROC CORR of SAS 9.4 and the statistical significance was set as P ≤ 0.05. The finger pulse oximeter could not measure heart and respiratory rates in cows with pigmented teats. There was a high correlation between the stethoscope heart rate and pulse oximeter heart rate of front and, especially, rear teats (r = 0.79; and r = 0.85, respectively; P < 0.001). However, there was no correlation between the stethoscope respiratory rate and the finger pulse oximeter respiratory rate of front and rear teats (P ≥ 0.104). Similarly, there was no correlation between both front and rear teats and rectal temperatures (P ≥ 0.576). In conclusion, this study demonstrates that a finger pulse oximeter is a suitable tool for recording the heart rate in non-pigmented teats of dairy cows. However, further studies are needed to identify noninvasive methods for assessing respiratory rate and body temperature in dairy cows. | en_US |
dc.language | eng | en_US |
dc.subject | 310904 Medicina interna | en_US |
dc.subject | 3104 Producción Animal | en_US |
dc.subject | 310402 Bovinos | en_US |
dc.title | Measuring heart rate, respiratory rate and body temperature using a finger pulse oximeter and an infrared thermometer in dairy cows | en_US |
dc.type | info:eu-repo/semantics/bachelorThesis | en_US |
dc.type | BachelorThesis | en_US |
dc.contributor.departamento | Departamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentos | en_US |
dc.contributor.facultad | Facultad de Veterinaria | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Trabajo final de grado | en_US |
dc.utils.revision | Sí | en_US |
dc.identifier.matricula | TFT-21547 | |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-VET | en_US |
dc.contributor.titulacion | Grado en Veterinaria | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.advisor.dept | GIR IUSA-ONEHEALTH 4. Producción y Biotecnología Animal | - |
crisitem.advisor.dept | IU de Sanidad Animal y Seguridad Alimentaria | - |
crisitem.advisor.dept | Departamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentos | - |
crisitem.advisor.dept | GIR IUSA-ONEHEALTH 4. Producción y Biotecnología Animal | - |
crisitem.advisor.dept | IU de Sanidad Animal y Seguridad Alimentaria | - |
crisitem.advisor.dept | GIR IUSA-ONEHEALTH 5: Reproducción Animal, Oncología y Anestesiología Comparadas | - |
crisitem.advisor.dept | IU de Sanidad Animal y Seguridad Alimentaria | - |
Colección: | Trabajo final de grado |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.