Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/133642
Título: Measuring heart rate, respiratory rate and body temperature using a finger pulse oximeter and an infrared thermometer in dairy cows
Autores/as: Hernández Rivero, Víctor Jesús
Director/a : Hernández Castellano, Lorenzo Enrique 
Gonzalez Cabrera, Marta 
Perez Acosta, Pablo 
Clasificación UNESCO: 310904 Medicina interna
3104 Producción Animal
310402 Bovinos
Fecha de publicación: 2024
Resumen: Heart rate, respiratory rate, and body temperature are crucial indicators of animal health and welfare. Traditionally, heart and respiratory rates are often monitored with a stethoscope, while body temperature is measured rectally. These methods require handling the animals, which could potentially cause stress. Given the significance of these physiological parameters, this study aims to validate non-invasive techniques for measuring heart and respiratory rates with a human finger pulse oximeter and body temperature with an infrared thermometer. The study involved 40 Holstein Friesian cows at various lactation stages. The experiment was conducted in an alleyway using batches of 3-4 animals immediately after the morning milking. Heart and respiratory rates were measured using a stethoscope and a finger pulse oximeter, which were placed on both pigmented and non-pigmented teats, as well as on front and rear teats. Infrared temperatures of both front and rear teats were measured with an infrared thermometer, and rectal temperature was recorded with a digital thermometer. The Pearson correlation coefficient was determined using the PROC CORR of SAS 9.4 and the statistical significance was set as P ≤ 0.05. The finger pulse oximeter could not measure heart and respiratory rates in cows with pigmented teats. There was a high correlation between the stethoscope heart rate and pulse oximeter heart rate of front and, especially, rear teats (r = 0.79; and r = 0.85, respectively; P < 0.001). However, there was no correlation between the stethoscope respiratory rate and the finger pulse oximeter respiratory rate of front and rear teats (P ≥ 0.104). Similarly, there was no correlation between both front and rear teats and rectal temperatures (P ≥ 0.576). In conclusion, this study demonstrates that a finger pulse oximeter is a suitable tool for recording the heart rate in non-pigmented teats of dairy cows. However, further studies are needed to identify noninvasive methods for assessing respiratory rate and body temperature in dairy cows.
Departamento: Departamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentos
Facultad: Facultad de Veterinaria
Titulación: Grado en Veterinaria
URI: http://hdl.handle.net/10553/133642
Colección:Trabajo final de grado

En el caso de que no encuentre el documento puede ser debido a que el centro o las/os autoras/es no autorizan su publicación. Si tiene verdadero interés en el contenido del mismo, puede dirigirse al director/a o directores/as del trabajo cuyos datos encontrará más arriba.

Vista completa

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.