Please use this identifier to cite or link to this item:
https://accedacris.ulpgc.es/handle/10553/129822
DC Field | Value | Language |
---|---|---|
dc.contributor.author | León, Raquel | en_US |
dc.contributor.author | Fabelo, Himar | en_US |
dc.contributor.author | Ortega, Samuel | en_US |
dc.contributor.author | Pineiro, Juan F. | en_US |
dc.contributor.author | Szolna, Adam | en_US |
dc.contributor.author | Morera, Jesus | en_US |
dc.contributor.author | Clavo, Bernardino | en_US |
dc.contributor.author | Callicó, Gustavo M. | en_US |
dc.date.accessioned | 2024-04-09T11:47:20Z | - |
dc.date.available | 2024-04-09T11:47:20Z | - |
dc.date.issued | 2023 | en_US |
dc.identifier.isbn | 9798350344196 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | https://accedacris.ulpgc.es/handle/10553/129822 | - |
dc.description.abstract | The purpose of this paper is to outline the advances in hyperspectral (HS) image fusion for intraoperative delineation of brain tumor tissue. HS images were acquired using an intraoperative acquisition system based on two push-broom HS cameras, one covering the visible and near-infrared (VNIR) [400-1000 nm] and the other the near-infrared (NIR) [900-1700 nm] spectral range. A dataset of a wide range of in-vivo brain cancer acquired during neurosurgical procedures with both HS cameras was used to compare the performance results of using the VNIR and NIR data, independently and combining the VNIR-NIR data. Classification maps obtained using the fused VNIR-NIR images provide more accurate classification, removing false positives that appear when the VNIR and NIR images are processed independently. | en_US |
dc.language | eng | en_US |
dc.source | Proceedings - 2023 26th Euromicro Conference on Digital System Design, DSD 2023[EISSN ], p. 493-499, (Enero 2023) | en_US |
dc.subject | 3314 Tecnología médica | en_US |
dc.subject.other | Brain Tumors | en_US |
dc.subject.other | Hyperspectral Imaging | en_US |
dc.subject.other | Image Registration | en_US |
dc.subject.other | Visual And Near-Infrared | en_US |
dc.title | Evaluation of Hyperspectral Imaging Fusion for in-vivo Brain Tumor Identification and Delineation | en_US |
dc.type | info:eu-repo/semantics/conferenceObject | en_US |
dc.type | ConferenceObject | en_US |
dc.relation.conference | 26th Euromicro Conference on Digital System Design (DSD 2023) | en_US |
dc.identifier.doi | 10.1109/DSD60849.2023.00074 | en_US |
dc.identifier.scopus | 85189173444 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.authorscopusid | 57212456639 | - |
dc.contributor.authorscopusid | 56405568500 | - |
dc.contributor.authorscopusid | 57189334144 | - |
dc.contributor.authorscopusid | 57189323824 | - |
dc.contributor.authorscopusid | 14032568700 | - |
dc.contributor.authorscopusid | 35466252100 | - |
dc.contributor.authorscopusid | 57190093030 | - |
dc.contributor.authorscopusid | 56006321500 | - |
dc.description.lastpage | 499 | en_US |
dc.description.firstpage | 493 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Actas de congresos | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Enero 2023 | en_US |
dc.identifier.conferenceid | events152802 | - |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-TEL | en_US |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | GIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | GIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | GIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.orcid | 0000-0002-4287-3200 | - |
crisitem.author.orcid | 0000-0002-9794-490X | - |
crisitem.author.orcid | 0000-0002-7519-954X | - |
crisitem.author.orcid | 0000-0002-3784-5504 | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.fullName | León Martín,Sonia Raquel | - |
crisitem.author.fullName | Fabelo Gómez, Himar Antonio | - |
crisitem.author.fullName | Ortega Sarmiento,Samuel | - |
crisitem.author.fullName | Marrero Callicó, Gustavo Iván | - |
crisitem.event.eventsstartdate | 07-09-2009 | - |
crisitem.event.eventsenddate | 11-09-2009 | - |
Appears in Collections: | Actas de congresos |
SCOPUSTM
Citations
1
checked on Mar 30, 2025
WEB OF SCIENCETM
Citations
1
checked on Mar 30, 2025
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.