Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/128254
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Bordón Pérez, Pablo Rubén | en_US |
dc.contributor.author | Cuadrado Hernández, Alberto Javier | en_US |
dc.contributor.author | Paz Hernández, Rubén | en_US |
dc.contributor.author | Navarro Gonzalo, Álvaro | en_US |
dc.contributor.author | Monzón Verona, Mario Domingo | en_US |
dc.contributor.author | Rivero Lopez,Yamilet | en_US |
dc.contributor.author | Garcia Montagut, Carlos Joshua | en_US |
dc.contributor.author | Yánez Santana, Manuel Alejandro | en_US |
dc.contributor.author | Ruiz Alzola, Juan Bautista | en_US |
dc.date.accessioned | 2024-01-08T13:17:13Z | - |
dc.date.available | 2024-01-08T13:17:13Z | - |
dc.date.issued | 2024 | en_US |
dc.identifier.issn | 0012-7361 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/128254 | - |
dc.description.abstract | Orthopedic splints are widely used to immobilize parts of the body during the recovery from bone injuries, surgeries, or post-traumatic recovery. In the medical field, there are two main types of splints: the rigid and disposable ones made of plaster, and the non-disposable but detachable ones, typically made up of metallic and polymeric components. Rigid splints are economical and can be quickly applied, but they have limitations in terms of weight, ventilation, and comfort, and also require medical staff intervention for their removal. On the other hand, detachable splints offer greater comfort and breathability, but they are more expensive and their fit to the patient is less accurate. This work presents the development of personalized orthopedic splints, lighter and more breathable, at a reasonable cost and production time. To achieve this, a methodology is proposed that includes an economical scanning of the area to be immobilized, an accessible and efficient digital design, and its production using MEX additive manufacturing technology, meeting the necessary mechanical requirements for immobilization and stiffness, based on finite element simulations. This proposal is presented as an alternative to conventional splints, offering improved performance thanks to affordable and low-cost additive manufacturing technologies. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Dyna (Bilbao) | en_US |
dc.source | Dyna: Ingeniería e Indiustria [ISSN 0023-7361; eISSN 1989-1490], v. 99 (4), p. 347-352 | en_US |
dc.subject | 321310 Cirugía ortopédica | en_US |
dc.subject | 331402 Prótesis | en_US |
dc.subject | 3328 Procesos tecnológicos | en_US |
dc.subject.other | Fabricación digital | en_US |
dc.subject.other | Inmovilización médica | en_US |
dc.subject.other | Escaneado tridimensional | en_US |
dc.subject.other | Extrusión de material | en_US |
dc.subject.other | Digital manufacturing | en_US |
dc.subject.other | Medical immobilization | en_US |
dc.subject.other | Three-dimensional scanning | en_US |
dc.subject.other | Material extrusion | en_US |
dc.title | Methodological development of personalized orthopedic splints through low-cost additive manufacturing | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.6036/11081 | en_US |
dc.identifier.scopus | 85184498115 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.authorscopusid | 58872149700 | - |
dc.contributor.authorscopusid | 58871783100 | - |
dc.contributor.authorscopusid | 58871783200 | - |
dc.contributor.authorscopusid | 58872024500 | - |
dc.contributor.authorscopusid | 58872515000 | - |
dc.contributor.authorscopusid | 58871783300 | - |
dc.contributor.authorscopusid | 58871783400 | - |
dc.contributor.authorscopusid | 58872395900 | - |
dc.contributor.authorscopusid | 56614041800 | - |
dc.identifier.eissn | 1989-1490 | - |
dc.identifier.issue | 0 | - |
dc.description.firstpage | 347 | en_US |
dc.relation.volume | 99 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 10 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | 2023 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-ING | en_US |
dc.description.sjr | 0,157 | - |
dc.description.jcr | 1,0 | - |
dc.description.sjrq | Q4 | - |
dc.description.jcrq | Q4 | - |
dc.description.sellofecyt | Sello FECYT | |
dc.description.scie | SCIE | |
dc.description.miaricds | 11,0 | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR Fabricación integrada y avanzada | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Fabricación integrada y avanzada | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Fabricación integrada y avanzada | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Fabricación integrada y avanzada | - |
crisitem.author.dept | GIR Fabricación integrada y avanzada | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.orcid | 0000-0002-3148-2677 | - |
crisitem.author.orcid | 0000-0002-8599-781X | - |
crisitem.author.orcid | 0000-0003-1223-7067 | - |
crisitem.author.orcid | 0000-0003-2736-7905 | - |
crisitem.author.orcid | 0000-0002-5587-0092 | - |
crisitem.author.orcid | 0000-0002-1736-552X | - |
crisitem.author.orcid | 0000-0002-3545-2328 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Bordón Pérez, Pablo Rubén | - |
crisitem.author.fullName | Cuadrado Hernández, Alberto Javier | - |
crisitem.author.fullName | Paz Hernández, Rubén | - |
crisitem.author.fullName | Monzón Verona, Mario Domingo | - |
crisitem.author.fullName | Rivero Lopez, Yamilet | - |
crisitem.author.fullName | Garcia Montagut, Carlos Joshua | - |
crisitem.author.fullName | Yánez Santana, Manuel Alejandro | - |
crisitem.author.fullName | Ruiz Alzola, Juan Bautista | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.