Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/121697
Título: Experimental Research on New Developed Titanium Alloys for Biomedical Applications
Autores/as: Jimenez-Marcos, C
Mirza Rosca, Julia Claudia 
Baltatu, MS
Vizureanu, P
Clasificación UNESCO: 331209 Resistencia de materiales
330307 Tecnología de la corrosión
320714 Osteopatología
Palabras clave: titanium alloys
Ti20Mo7Zr
Ti20Mo7Zr0
5Si
microstructure, et al.
Fecha de publicación: 2022
Publicación seriada: Bioengineering 
Resumen: The mechanical properties and electrochemical behavior of two new titanium alloys, Ti20Mo7Zr and Ti20Mo7Zr0.5Si, are investigated in this paper. The alloys have been manufactured by vacuum arc remelting (VAR) technique and studied to determine their microstructure, corrosion behavior, and mechanical properties. Metallographic observations and quantitative microanalysis by optical microscopy, scanning electron microscopy SEM, and energy dispersive X-rays spectroscopy EDX were performed. Data about the three-point bending test and microhardness are presented. For electrochemical properties, three different environments were used: Ringer solution at 25 °C, Ringer solution at 40 °C simulating fever condition, and 3.5% NaCl solution. Metallographic investigation revealed the biphasic and dendritic structure of both samples when the procedures were performed. Electrochemical testing in body simulation fluid, fever conditions, and saline medium showed that the lower the proportion of silicon in the samples, the higher the corrosion resistance. The formation of a titanium oxide layer on the surface of both samples was noticed using quantitative EDX analysis. The three-point bending test for the two samples revealed that the presence of silicon decreases the modulus of elasticity; the surface of the samples displayed soft and hard phases in the microhardness test. Electrochemical impedance spectroscopy (EIS) measurements were carried out at different potentials, and the obtained spectra exhibit a two-time constant system, attesting double-layer passive film on the samples.
URI: http://hdl.handle.net/10553/121697
ISSN: 2306-5354
DOI: 10.3390/bioengineering9110686
Colección:Artículos
Adobe PDF (6,65 MB)
Vista completa

Citas SCOPUSTM   

19
actualizado el 24-nov-2024

Citas de WEB OF SCIENCETM
Citations

18
actualizado el 24-nov-2024

Visitas

46
actualizado el 12-oct-2024

Descargas

26
actualizado el 12-oct-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.