Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/120695
Título: Echocardiographic Assessment of the Pulmonary Vein to Pulmonary Artery Ratio in Canine Heartworm Disease
Autores/as: Matos Rivero, Jorge Isidoro 
Caro Vadillo,Alicia 
Falcón Cordón, Yaiza 
García Rodríguez, Sara Nieves 
Costa Rodríguez, Noelia 
Carretón Gómez, Elena 
Montoya Alonso, José Alberto 
Clasificación UNESCO: 310904 Medicina interna
320501 Cardiología
320508 Enfermedades pulmonares
Palabras clave: Dirofilaria immitis
Heartworm disease
Pulmonary vein
Pulmonary artery
PV:PA ratio, et al.
Fecha de publicación: 2023
Publicación seriada: Animals 
Resumen: Dirofilaria immitis produces proliferative pulmonary endarteritis and pulmonary thromboembolism in infected dogs. The pulmonary vascular lesions lead to irreversible and persistent structural damage and, as a consequence, sustained precapillary pulmonary hypertension (PH). The purpose of this study was to assess the diagnostic value of the pulmonary vein to pulmonary artery ratio (PV:PA ratio) to determine moderate or severe PH (>50 mmHg) in dogs with heartworm disease. Methods: A total of 151 naturally heartworm-infected and 66 healthy dogs were included in the study. The presence/absence of PH was based on the right pulmonary artery distensibility index (RPAD index < 29.5%), and the PV:PA ratio was echocardiographically measured by the time–motion mode (M mode) and two-dimensional mode (2D mode). Other echocardiographic parameters were also assessed (pulmonary trunk to aorta ratio, tricuspid regurgitation pressure gradient, and AT:ET ratio). Results: The results of the PV:PA ratio showed a highly positive correlation between the M and 2D modes (r = 0.928). The PV:PA ratio obtained by the M mode was identified as the strongest predictor for RPAD index (R2 0.628, p < 0.0001) with a good diagnostic accuracy (AUC = 0.99). The results of PV/PA by the 2D mode showed a similar prediction for the RPAD index (R2 0.606, p < 0.0001) with a good diagnostic accuracy (AUC = 0.98). Both of the 2D and M modes’ PV:PA ratios decreased significantly with the presence of PH. A cut-off value of ≤0.845 showed high sensitivity and specificity for the M mode (97% and 94%, respectively) and the 2D mode (96% and 93%, respectively). Conclusions: The PV:PA ratio may be useful as a complementary diagnostic method for the estimation of moderate or severe PH in dogs with heartworm.
URI: http://hdl.handle.net/10553/120695
ISSN: 2076-2615
DOI: 10.3390/ani13040703
Fuente: Animals [ISSN 2076-2615], v. 13(4)
Colección:Artículos
Adobe PDF (1,48 MB)
Vista completa

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.