Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/119638
Campo DC Valoridioma
dc.contributor.authorBarroso Rosa, Sergioen_US
dc.contributor.authorHazratwala, Kaushiken_US
dc.contributor.authorWilkinson, Matthew P.R.en_US
dc.date.accessioned2022-12-12T15:39:53Z-
dc.date.available2022-12-12T15:39:53Z-
dc.date.issued2022en_US
dc.identifier.issn0942-2056en_US
dc.identifier.otherScopus-
dc.identifier.urihttp://hdl.handle.net/10553/119638-
dc.description.abstractPurpose: In up to a fifth of total knee replacements (TKR), surgeons are not capable of achieving good clinical and functional results. Despite comprehensive diagnostic workup, an underlying cause is not always identified in these patients. The purpose of this study is to compare native and prosthetic trochlear anatomies, to evaluate a potential source of morphologic mismatch and theoretically, of poor clinical outcomes. Methods: Native trochlear angles of 4116 knee CTs from 360 Knee Systems database of arthritic pre-operative TKR patients were evaluated. A semi-automated tridimensional analysis was performed to define the native trochlear angle in the coronal plane (NTA) among other 142 parameters. An active search was conducted to identify currently available TKR models; prosthetic trochlear orientation in the coronal plane (PTA) was extracted from the technical data provided by manufacturers. Results: The mean native trochlear angle (NTA) was 1.6° ± 6.6° (valgus) with a range from − 23.8° (varus) to 30.3°(valgus). A valgus NTA was present in 60.6% of the knees and 39.4% of them had a varus NTA. 89 TKR models were identified; trochlear details were available for 45 of them, of which 93% were designed with a valgus orientation of the prosthetic trochlear angle (PTA) and 6.9% showed a neutral (0°) PTA. Varus alignment of PTA was not present in any system. Angular numeric values for PTA were available for 34 models; these ranged from 0° to 15° of valgus, with a median value of 6.18° (SD ± 2.88°). Conclusion: This study shows a significant mismatch between native and prosthetic trochlear angles. A relevant proportion of the studied knees (41.45%) fall out of the trochlear angle range of currently available implants; representing a potential source for biomechanical imbalance. While further research is warranted to fully understand the clinical implications of the present study, manufacturers may need to take these findings into account for future implant designs. Level of evidence: Level III, retrospective cohort study.en_US
dc.languageengen_US
dc.relation.ispartofKnee Surgery, Sports Traumatology, Arthroscopyen_US
dc.sourceKnee Surgery, Sports Traumatology, Arthroscopy[ISSN 0942-2056], (Enero 2022)en_US
dc.subject32 Ciencias médicasen_US
dc.subject321315 Traumatologíaen_US
dc.subject.otherOsteoarthritisen_US
dc.subject.otherPatellofemoral Jointen_US
dc.subject.otherProsthesis Designen_US
dc.subject.otherTotal Knee Replacementen_US
dc.titleMismatch between trochlear coronal alignment of arthritic knees and currently available prosthesis: a morphological analysis of 4116 knees and 45 implant designsen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1007/s00167-022-07251-5en_US
dc.identifier.scopus85143242097-
dc.contributor.orcid0000-0002-7120-9763-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.authorscopusid57163915900-
dc.contributor.authorscopusid6506986077-
dc.contributor.authorscopusid57162202600-
dc.identifier.eissn1433-7347-
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.utils.revisionen_US
dc.date.coverdateEnero 2022en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-MEDen_US
dc.description.sjr1,789
dc.description.jcr3,8
dc.description.sjrqQ1
dc.description.jcrqQ1
dc.description.scieSCIE
dc.description.miaricds10,9
item.fulltextCon texto completo-
item.grantfulltextopen-
crisitem.author.deptGIR IUIBS: Nutrición-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.orcid0000-0002-7120-9763-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameBarroso Rosa, Sergio-
Colección:Artículos
Adobe PDF (929,66 kB)
Vista resumida

Citas SCOPUSTM   

10
actualizado el 17-nov-2024

Citas de WEB OF SCIENCETM
Citations

9
actualizado el 17-nov-2024

Visitas

26
actualizado el 14-oct-2023

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.