Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/119404
Campo DC Valoridioma
dc.contributor.authorDíaz González, Candelaria Merceden_US
dc.contributor.authorDe La Rosa Hormiga, Milagrosen_US
dc.contributor.authorRamal López, Josefa Maríaen_US
dc.contributor.authorDeniz Rivero, Yasminaen_US
dc.contributor.authorMarrero Morales, María Sandraen_US
dc.date.accessioned2022-11-25T17:41:03Z-
dc.date.available2022-11-25T17:41:03Z-
dc.date.issued2014en_US
dc.identifier.issn0973-709Xen_US
dc.identifier.urihttp://hdl.handle.net/10553/119404-
dc.description.abstractIntroduction: Oxygen saturation is considered as the 5(th) vital sign. Presently, there exist fixed and wireless pulse oximeters, being the latter most widely used in the last years. Some of them have no possibility of calibration. This situation leads the health staff to adopt therapeutic attitudes which can be wrong. Therefore, it is extremely important to know if these wireless oximeters show a right concordance as regards measurements, since it is of great interest in daily clinical practice. Objective: To evaluate concordance among measurements obtained by three different pulse oximeters currently used by health professionals. Materials and methods: This is an observational, descriptive and cross-sectional study related to the concordance of the results obtained in measurements collected by three different pulse oximeters (one monitor and two wireless oximeters) which are available and in use in this hospital unit. The sample size calculation was performed for a concordance above 0.81 and an estimation error which did not exceed 0.20. The intraclass correlation index (ICI) was used to establish the concordance whereas the Landis-Koch criteria were used to interpret the results. Systematic errors were analyzed using the Bland-Altman plot. Results: The overall concordance among the three pulse oximeters analyzed resulted in 0.88, a value considered as "good" according to the Landis-Koch criteria. Conclusion: The results obtained show that in daily clinical practice both wireless pulse oximeters analyzed can be used with a certain reliability, taking into account the limitations of this research.en_US
dc.languageengen_US
dc.relation.ispartofJournal of Clinical and Diagnostic Researchen_US
dc.sourceJournal of Clinical and Diagnostic Research [0973-709X], v. 8(8), pp.9-12 (Agosto 2014)en_US
dc.subject32 Ciencias médicasen_US
dc.subject3201 Ciencias clínicasen_US
dc.subject.otherGasesen_US
dc.subject.otherMonitoringen_US
dc.subject.otherOximetryen_US
dc.subject.otherPulse oximeteren_US
dc.titleConcordance among measurements obtained by three pulse oximeters currently used by health professionals.en_US
dc.typeinfo:eu-repo/semantics/articleen_US
dc.typeArticleen_US
dc.identifier.doi10.7860/JCDR/2014/8874.4763en_US
dc.description.lastpage12en_US
dc.identifier.issue8-
dc.description.firstpage9en_US
dc.relation.volume8en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.description.numberofpages4en_US
dc.utils.revisionen_US
dc.date.coverdateAgosto 2014en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-MEDen_US
dc.description.sjr0,27
dc.description.sjrqQ2
item.fulltextCon texto completo-
item.grantfulltextopen-
crisitem.author.deptGIR IUIBS: Nutrición-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Enfermería-
crisitem.author.deptGIR IUIBS: Nutrición-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Enfermería-
crisitem.author.deptGIR IUIBS: Nutrición-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Enfermería-
crisitem.author.deptGIR Lingüística aplicada a la docencia de la lengua extranjera, su literatura y traducción-
crisitem.author.deptDepartamento de Filología Moderna, Traducción e Interpretación-
crisitem.author.orcid0000-0003-1797-4752-
crisitem.author.orcid0000-0002-6768-0982-
crisitem.author.orcid0000-0002-6409-1787-
crisitem.author.orcid0000-0002-9120-3772-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgDepartamento de Filología Moderna, Traducción e Interpretación-
crisitem.author.fullNameDíaz González, Candelaria Merced-
crisitem.author.fullNameDe La Rosa Hormiga, Milagros-
crisitem.author.fullNameRamal López, Josefa María-
crisitem.author.fullNameMarrero Morales, María Sandra-
Colección:Artículos
Adobe PDF (256,03 kB)
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.