Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/119035
Campo DC Valoridioma
dc.contributor.authorManchado Herrera, Ignacioen_US
dc.contributor.authorMotta, Luci M.en_US
dc.contributor.authorBlanco, Gustavoen_US
dc.contributor.authorGonzález, Jesúsen_US
dc.contributor.authorGarcés Martín, Gerardoen_US
dc.date.accessioned2022-10-24T14:27:43Z-
dc.date.available2022-10-24T14:27:43Z-
dc.date.issued2022en_US
dc.identifier.issn2077-0383en_US
dc.identifier.otherScopus-
dc.identifier.urihttp://hdl.handle.net/10553/119035-
dc.description.abstractThere is some controversy regarding the use of one or two hamstring tendons for anterior cruciate ligament reconstruction (ACLR). In this study, two cohorts of 22 male patients underwent an ACLR with hamstring tendon autografts. One cohort was reconstructed through an all-inside technique with the semitendinosus tendon (ST group) and the other with the semitendinosus and gracilis tendons (ST-G group). Anterior tibial translation (ATT), Lysholm, and IKDC scores were assessed preoperatively and five years postoperation. Additionally, isometric knee muscle strength was manually measured in both groups and in another cohort of 22 uninjured control male subjects five years after the operation. There were no significant differences in ATT and Lysholm scores between the operated groups. The IKDC score was lower in the ST-G group than in the ST group—9.57 (CI 14.89–4.25) (p < 0.001). No significant differences between injured and uninjured knees were detected in hamstring to quadriceps ratio strength and quadriceps limb symmetry index of the two operated groups, but the hamstring limb symmetry index was significantly lower in the ST-G group than in the ST and control groups. This study shows that using an ST-G autograft for ACLR yielded less flexor strength and worse results in some patient-reported outcome measures (PROM) than using an ST autograft five years after the operation. The observed results let us suggest that the use of one autograft hamstring tendon for ACLR is clinically preferable to the use of two hamstring tendons.en_US
dc.languageengen_US
dc.relation.ispartofJournal of Clinical Medicineen_US
dc.sourceJournal of Clinical Medicine[EISSN 2077-0383],v. 11 (19), (Octubre 2022)en_US
dc.subject32 Ciencias médicasen_US
dc.subject3213 Cirugíaen_US
dc.subject.otherAnterior Cruciate Ligamenten_US
dc.subject.otherHamstring Tendon Graften_US
dc.subject.otherIkdcen_US
dc.subject.otherKnee Strengthen_US
dc.subject.otherLysholmen_US
dc.titleIsometric Knee Muscle Strength and Patient-Reported Measures Five Years after Anterior Cruciate Ligament Reconstruction: Comparison of Single versus Dual Autograft Hamstring Tendon Harvestingen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.3390/jcm11195682en_US
dc.identifier.scopus85139778223-
dc.contributor.orcid0000-0002-8512-6141-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.orcid0000-0001-6816-4157-
dc.contributor.orcid0000-0003-4494-9077-
dc.contributor.authorscopusid57374819100-
dc.contributor.authorscopusid57221261711-
dc.contributor.authorscopusid57221263829-
dc.contributor.authorscopusid57204456054-
dc.contributor.authorscopusid56406565300-
dc.identifier.eissn2077-0383-
dc.identifier.issue19-
dc.relation.volume11en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.description.numberofpages12en_US
dc.utils.revisionen_US
dc.date.coverdateOctubre 2022en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-MEDen_US
dc.description.sjr0,935
dc.description.jcr3,9
dc.description.sjrqQ1
dc.description.jcrqQ2
dc.description.scieSCIE
dc.description.miaricds10,5
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptDepartamento de Enfermería-
crisitem.author.deptGIR Biomaterials and Biomechanics Research Group-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.orcid0000-0002-8512-6141-
crisitem.author.orcid0000-0003-4494-9077-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.fullNameManchado Herrera, Ignacio-
crisitem.author.fullNameGarcés Martín, Gerardo-
Colección:Artículos
Adobe PDF (428,26 kB)
Vista resumida

Citas SCOPUSTM   

1
actualizado el 08-dic-2024

Citas de WEB OF SCIENCETM
Citations

1
actualizado el 08-dic-2024

Visitas

29
actualizado el 09-mar-2024

Descargas

9
actualizado el 09-mar-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.