Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/119035
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Manchado Herrera, Ignacio | en_US |
dc.contributor.author | Motta, Luci M. | en_US |
dc.contributor.author | Blanco, Gustavo | en_US |
dc.contributor.author | González, Jesús | en_US |
dc.contributor.author | Garcés Martín, Gerardo | en_US |
dc.date.accessioned | 2022-10-24T14:27:43Z | - |
dc.date.available | 2022-10-24T14:27:43Z | - |
dc.date.issued | 2022 | en_US |
dc.identifier.issn | 2077-0383 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/119035 | - |
dc.description.abstract | There is some controversy regarding the use of one or two hamstring tendons for anterior cruciate ligament reconstruction (ACLR). In this study, two cohorts of 22 male patients underwent an ACLR with hamstring tendon autografts. One cohort was reconstructed through an all-inside technique with the semitendinosus tendon (ST group) and the other with the semitendinosus and gracilis tendons (ST-G group). Anterior tibial translation (ATT), Lysholm, and IKDC scores were assessed preoperatively and five years postoperation. Additionally, isometric knee muscle strength was manually measured in both groups and in another cohort of 22 uninjured control male subjects five years after the operation. There were no significant differences in ATT and Lysholm scores between the operated groups. The IKDC score was lower in the ST-G group than in the ST group—9.57 (CI 14.89–4.25) (p < 0.001). No significant differences between injured and uninjured knees were detected in hamstring to quadriceps ratio strength and quadriceps limb symmetry index of the two operated groups, but the hamstring limb symmetry index was significantly lower in the ST-G group than in the ST and control groups. This study shows that using an ST-G autograft for ACLR yielded less flexor strength and worse results in some patient-reported outcome measures (PROM) than using an ST autograft five years after the operation. The observed results let us suggest that the use of one autograft hamstring tendon for ACLR is clinically preferable to the use of two hamstring tendons. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Clinical Medicine | en_US |
dc.source | Journal of Clinical Medicine[EISSN 2077-0383],v. 11 (19), (Octubre 2022) | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 3213 Cirugía | en_US |
dc.subject.other | Anterior Cruciate Ligament | en_US |
dc.subject.other | Hamstring Tendon Graft | en_US |
dc.subject.other | Ikdc | en_US |
dc.subject.other | Knee Strength | en_US |
dc.subject.other | Lysholm | en_US |
dc.title | Isometric Knee Muscle Strength and Patient-Reported Measures Five Years after Anterior Cruciate Ligament Reconstruction: Comparison of Single versus Dual Autograft Hamstring Tendon Harvesting | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/jcm11195682 | en_US |
dc.identifier.scopus | 85139778223 | - |
dc.contributor.orcid | 0000-0002-8512-6141 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | 0000-0001-6816-4157 | - |
dc.contributor.orcid | 0000-0003-4494-9077 | - |
dc.contributor.authorscopusid | 57374819100 | - |
dc.contributor.authorscopusid | 57221261711 | - |
dc.contributor.authorscopusid | 57221263829 | - |
dc.contributor.authorscopusid | 57204456054 | - |
dc.contributor.authorscopusid | 56406565300 | - |
dc.identifier.eissn | 2077-0383 | - |
dc.identifier.issue | 19 | - |
dc.relation.volume | 11 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 12 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Octubre 2022 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.sjr | 0,935 | |
dc.description.jcr | 3,9 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
dc.description.miaricds | 10,5 | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | Departamento de Enfermería | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0002-8512-6141 | - |
crisitem.author.orcid | 0000-0003-4494-9077 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Manchado Herrera, Ignacio | - |
crisitem.author.fullName | Garcés Martín, Gerardo | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
1
checked on Mar 30, 2025
WEB OF SCIENCETM
Citations
1
checked on Mar 30, 2025
Page view(s)
29
checked on Mar 9, 2024
Download(s)
9
checked on Mar 9, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.