dc.contributor.author | Yánez Santana, Manuel Alejandro | en_US |
dc.contributor.author | Fiorucci, Maria Paula | en_US |
dc.contributor.author | Martel Fuentes, Oscar | en_US |
dc.contributor.author | Cuadrado Hernández, Alberto Javier | en_US |
dc.date.accessioned | 2022-09-27T10:15:43Z | - |
dc.date.available | 2022-09-27T10:15:43Z | - |
dc.date.issued | 2022 | en_US |
dc.identifier.issn | 1996-1944 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/118647 | - |
dc.description.abstract | Powder bed fusion technology has undergone a remarkable amount of development in recent years in the field of medical implants due to the advantages associated with it. In many implant applications that demand loads in parts with a high degree of roughness and small dimensions, the mechanical properties, especially fatigue properties, play a key role in the success of the implants. One of the most used materials in this field is Ti-6Al-4V. On the other hand, the high cost of titanium powders makes it necessary to search for suitable powder recycling strategies. In this work, the effects of dimensions and powder recycling on the roughness and the mechanical properties of cylinder specimens were obtained from tensile static and fatigue tests of Ti-6Al4V Extra-Low Interstitial (ELI) parts. Four types of specimens were fabricated by laser powder bed fusion (two dimensions (section diameters of 2 mm and 5 mm) with new powder and with recycled powder). Results show that the oxygen concentration increased with recycling. No significant effects of recycling were observed on the monotonic tensile strength specimens. However, specimens fabricated with recycled powder showed greater roughness, lower ductility, and lower fatigue strength than those fabricated with new powder. On the other hand, the 5-mm-diameter specimens showed slightly better fatigue behavior than the 2-mm-diameter ones. | en_US |
dc.language | eng | en_US |
dc.relation | Análisis Biomecánicoy Biológico de la Combinación de Sistema de Osteosíntesisy Scaffold Para la Reparación de Defectos Óseos Segmentarios | en_US |
dc.relation.ispartof | Materials | en_US |
dc.source | Materials [EISSN 1996-1944], v. 15 (16), 5787,(Agosto 2022) | en_US |
dc.subject | 3314 Tecnología médica | en_US |
dc.subject.other | Fatigue Behavior | en_US |
dc.subject.other | Laser Powder Bed Fusion | en_US |
dc.subject.other | Powder Recycling | en_US |
dc.subject.other | Surface Roughness | en_US |
dc.subject.other | Titanium Alloys | en_US |
dc.title | The Influence of Dimensions and Powder Recycling on the Roughness and Mechanical Properties of Ti-6Al-4V Parts Fabricated by Laser Powder Bed Fusion | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/ma15165787 | en_US |
dc.identifier.scopus | 85137683886 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | 0000-0002-4532-7520 | - |
dc.contributor.orcid | 0000-0003-3806-5523 | - |
dc.contributor.orcid | 0000-0002-8599-781X | - |
dc.contributor.authorscopusid | 56423836100 | - |
dc.contributor.authorscopusid | 50561152800 | - |
dc.contributor.authorscopusid | 15048342800 | - |
dc.contributor.authorscopusid | 7005588567 | - |
dc.identifier.eissn | 1996-1944 | - |
dc.identifier.issue | 16 | - |
dc.relation.volume | 15 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Agosto 2022 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-ING | en_US |
dc.description.sjr | 0,563 | - |
dc.description.jcr | 3,4 | - |
dc.description.sjrq | Q2 | - |
dc.description.jcrq | Q2 | - |
dc.description.scie | SCIE | - |
dc.description.miaricds | 10,6 | |
item.fulltext | Con texto completo | - |
item.grantfulltext | open | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.orcid | 0000-0002-1736-552X | - |
crisitem.author.orcid | 0000-0002-4532-7520 | - |
crisitem.author.orcid | 0000-0003-3806-5523 | - |
crisitem.author.orcid | 0000-0002-8599-781X | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Yánez Santana, Manuel Alejandro | - |
crisitem.author.fullName | Fiorucci,Maria Paula | - |
crisitem.author.fullName | Martel Fuentes, Oscar | - |
crisitem.author.fullName | Cuadrado Hernández, Alberto Javier | - |
crisitem.project.principalinvestigator | Yánez Santana, Manuel Alejandro | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
13
checked on Mar 30, 2025
WEB OF SCIENCETM
Citations
12
checked on Mar 30, 2025
Page view(s)
116
checked on Dec 14, 2024
Download(s)
67
checked on Dec 14, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.