Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/117199
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Ramos De Miguel, Ángel | en_US |
dc.contributor.author | Riol Sancho, Diego | en_US |
dc.contributor.author | Falcon Gonzalez, Juan Carlos | en_US |
dc.contributor.author | Pavone, Joana | en_US |
dc.contributor.author | Rodríguez Herrera, Leandro | en_US |
dc.contributor.author | Borkoski Barreiro, Silvia | en_US |
dc.contributor.author | Falcón Benítez, Nadia | en_US |
dc.contributor.author | Ramos Macías, Ángel Manuel | en_US |
dc.date.accessioned | 2022-07-18T13:40:16Z | - |
dc.date.available | 2022-07-18T13:40:16Z | - |
dc.date.issued | 2022 | en_US |
dc.identifier.issn | 2077-0383 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/117199 | - |
dc.description.abstract | New cochlear implant (CI) electrode arrays provide softer insertion dynamics; however, due to their high flexibility, the possibilities of fold-overs or intraoperative displacements must be taken into account. The position of each individual electrode can only be determined by using high-resolution computed tomography or cone-beam CT. The trans-impedance matrix test (TIM) is an electrophysiological method based on electric field imaging that can provide images of electrode position and electrode folding. Objective: In this experimental research, we evaluated the result of TIM as a method of monitoring cochlear insertion for a precurved slim modiolar electrode array in fresh human temporal bones by analyzing the transimpedance matrix patterns and their correlation with electrode position using high-resolution computed tomography. Material and Methods: Sixteen slim modiolar electrode arrays were inserted into eight fresh Human Temporal Bones. Eight electrodes were inserted according to the correct methodology of insertion, and eight were intentionally folded over. After all insertions, a trans-impedance matrix analysis and a Cone Beam CT (CBCT) were performed in each temporal bone. Results: If we correlated the TIM patterns with the radiological electrode position, we observed that better electrode intracochlear positions indicated more “homogeneous” TIM patterns (intracochlear voltage dropped monotonically as the distance between stimulation and recording contact increased, both toward the apex and toward the base). A correlation where fold-over was detected in the TIM results was found in all eight temporal bone radiological findings. Conclusions: Trans-Impedance Matrix patterns were correlated with the radiological CI electrode position. When a tip fold-over appeared, a matrix with a secondary ridge in addition to the primary ridge was observed in all cases. TIM can be an effective method in the control of electrode positioning. | en_US |
dc.language | eng | en_US |
dc.relation | Diseño, refinamiento y validación de modelos de elementos finitos para el estudio de implantes cocleares y vestibulares | en_US |
dc.relation | Diseño óptimo de implantes cocleares mediante simulación numérica | en_US |
dc.relation.ispartof | Journal of Clinical Medicine | en_US |
dc.source | Journal of Clinical Medicine[EISSN 2077-0383],v. 11 (14), (Julio 2022) | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 321305 Cirugía de garganta, nariz y oídos | en_US |
dc.subject.other | Cochlear Implant | en_US |
dc.subject.other | Fold-Over Of The Electrode | en_US |
dc.subject.other | Hearing Loss | en_US |
dc.subject.other | Perimodiolar Electrode Array | en_US |
dc.subject.other | Temporal Bone | en_US |
dc.subject.other | Trans Impedance | en_US |
dc.title | Assessing the Placement of the Cochlear Slim Perimodiolar Electrode Array by Trans Impedance Matrix Analysis: A Temporal Bone Study | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/jcm11143930 | en_US |
dc.identifier.scopus | 85133440822 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.authorscopusid | 56848284600 | - |
dc.contributor.authorscopusid | 57781697600 | - |
dc.contributor.authorscopusid | 36618690700 | - |
dc.contributor.authorscopusid | 57781170900 | - |
dc.contributor.authorscopusid | 57782225900 | - |
dc.contributor.authorscopusid | 55371597700 | - |
dc.contributor.authorscopusid | 57780909900 | - |
dc.contributor.authorscopusid | 7103172103 | - |
dc.identifier.eissn | 2077-0383 | - |
dc.identifier.issue | 14 | - |
dc.relation.volume | 11 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 12 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Julio 2022 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.sjr | 0,935 | |
dc.description.jcr | 3,9 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
dc.description.miaricds | 10,5 | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.project.principalinvestigator | Escobar Sánchez, José M | - |
crisitem.project.principalinvestigator | Escobar Sánchez, José M | - |
crisitem.author.dept | GIR SIANI: Modelización y Simulación Computacional | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Informática y Sistemas | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0002-0528-815X | - |
crisitem.author.orcid | 0000-0002-5743-4374 | - |
crisitem.author.orcid | 0000-0003-3569-0112 | - |
crisitem.author.orcid | 0000-0002-4709-5559 | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.fullName | Ramos De Miguel, Ángel | - |
crisitem.author.fullName | Falcon Gonzalez,Juan Carlos | - |
crisitem.author.fullName | Borkoski Barreiro,Silvia | - |
crisitem.author.fullName | Falcón Benítez, Nadia | - |
crisitem.author.fullName | Ramos Macías, Ángel Manuel | - |
Colección: | Artículos |
Citas SCOPUSTM
2
actualizado el 10-nov-2024
Citas de WEB OF SCIENCETM
Citations
2
actualizado el 10-nov-2024
Visitas
63
actualizado el 23-mar-2024
Descargas
34
actualizado el 23-mar-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.