Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/112201
DC Field | Value | Language |
---|---|---|
dc.contributor.author | León Zerpa, Federico Antonio | en_US |
dc.contributor.author | Ramos Martín, Alejandro | en_US |
dc.date.accessioned | 2021-10-11T08:10:04Z | - |
dc.date.available | 2021-10-11T08:10:04Z | - |
dc.date.issued | 2021 | en_US |
dc.identifier.issn | 2077-0375 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/112201 | - |
dc.description.abstract | Reverse osmosis (RO) is the most widely used technology for seawater desalination purposes. The long-term operating data of full-scale plants is key to analyse their performance under real conditions. The studied seawater reverse osmosis (SWRO) desalination plant had a production capacity of 5000 m3/d for irrigation purposes. The operating data such as conductivities flows, and pressures were collected for around 27,000 h for 4 years. The plant had sand and cartridge filters without chemical dosing in the pre-treatment stage, a RO system with one stage, 56 pressure vessels, seven RO membrane elements per pressure vessel and a Pelton turbine as energy recovery device. The operating data allowed to calculate the average water and salt permeability coefficients (A and B) of the membrane as well as the specific energy consumption (SEC) along the operating period. The calculation of the average A in long-term operation allowed to fit the parameters of three different models used to predict the mentioned parameter. The results showed a 30% decrease of A, parameter B increase around 70%. The SEC was between 3.75 and 4.25 kWh/m3. The three models fitted quite well to the experimental data with standard deviations between 0.0011 and 0.0015. | en_US |
dc.language | eng | en_US |
dc.relation | Mitigación del cambio climático a través de la innovación en el ciclo del agua mediante tecnologías bajas en carbono | en_US |
dc.relation.ispartof | Membranes | en_US |
dc.source | Membranes [e-ISSN 2077-0375], v. 11 (10), 774, (Octubre 2021) | en_US |
dc.subject | 330806 Regeneración del agua | en_US |
dc.subject | 3308 Ingeniería y tecnología del medio ambiente | en_US |
dc.subject.other | Seawater | en_US |
dc.subject.other | Reverse osmosis membranes | en_US |
dc.subject.other | Desalination | en_US |
dc.subject.other | Operating data | en_US |
dc.subject.other | Long-term | en_US |
dc.title | Performance Analysis of a Full-Scale Desalination Plant with Reverse Osmosis Membranes for Irrigation | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/membranes11100774 | en_US |
dc.identifier.scopus | 85120922368 | - |
dc.identifier.isi | WOS:000715695200001 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.authorscopusid | 57194451414 | - |
dc.contributor.authorscopusid | 57310454700 | - |
dc.identifier.eissn | 2077-0375 | - |
dc.description.lastpage | 11 | en_US |
dc.identifier.issue | 10 | - |
dc.description.firstpage | 1 | en_US |
dc.relation.volume | 11(10) | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.description.notas | This article belongs to the Special Issue Theoretical and Experimental Investigation of the Mass and Heat Transfers in Membrane Separation Processes | en_US |
dc.identifier.external | 101280019 | - |
dc.description.numberofpages | 11 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Octubre 2021 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-ING | en_US |
dc.description.sjr | 0,517 | - |
dc.description.jcr | 4,562 | - |
dc.description.sjrq | Q2 | - |
dc.description.jcrq | Q1 | - |
dc.description.scie | SCIE | - |
dc.description.miaricds | 10,5 | - |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.project.principalinvestigator | Pérez Báez,Sebastián Ovidio | - |
crisitem.author.dept | GIR IUNAT: Control analítico de fuentes medioambientales | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.dept | GIR IUNAT: Control analítico de fuentes medioambientales | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.orcid | 0000-0003-2284-8400 | - |
crisitem.author.orcid | 0000-0001-5759-4469 | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.fullName | León Zerpa, Federico Antonio | - |
crisitem.author.fullName | Ramos Martín, Alejandro | - |
Appears in Collections: | Artículos |
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.