Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/111900
DC FieldValueLanguage
dc.contributor.authorLeón Zerpa, Federico Antonioen_US
dc.contributor.authorRamos-Martín, Alejandroen_US
dc.date.accessioned2021-09-23T17:28:11Z-
dc.date.available2021-09-23T17:28:11Z-
dc.date.issued2021en_US
dc.identifier.issn1944-3994en_US
dc.identifier.otherScopus-
dc.identifier.urihttp://hdl.handle.net/10553/111900-
dc.description.abstractIn a previous paper, we proposed the construction of a new seawater intake in order to reduce the temperature range of the feed water, and a pilot plant for testing three types of low energy and high rejection membranes comparing performance and quality in a seawater reverse osmosis (SWRO) plant in the southeast of Spain. The results of the elements are shown. The conclusions of the study may serve as a tool for the decision‐making processes related to membrane replace-ment and retrofit projects whose designs were based on new high-efficiency membrane configura-tions in the plant. The selection of the element will be determined regarding the performance and energy costs of the pilot test.en_US
dc.languageengen_US
dc.relation.ispartofDesalination and Water Treatmenten_US
dc.sourceDesalination and Water Treatment [ISSN 1944-3994], v. 230, p. 25-32, (Agosto 2021)en_US
dc.subject3308 Ingeniería y tecnología del medio ambienteen_US
dc.subject.otherDesalinationen_US
dc.subject.otherHigh Efficiencyen_US
dc.subject.otherPilot Testingen_US
dc.subject.otherReverse Osmosisen_US
dc.subject.otherSeawateren_US
dc.titleResults of high-efficiency membrane pilot testing for membrane design optimizationen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.5004/dwt.2021.27465en_US
dc.identifier.scopus85114137666-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.authorscopusid57194451414-
dc.contributor.authorscopusid57225998020-
dc.identifier.eissn1944-3986-
dc.description.lastpage32en_US
dc.description.firstpage25en_US
dc.relation.volume230en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.utils.revisionen_US
dc.date.coverdateAgosto 2021en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-INGen_US
dc.description.sjr0,24
dc.description.jcr1,273
dc.description.sjrqQ3
dc.description.jcrqQ4
dc.description.scieSCIE
dc.description.miaricds10,6
item.fulltextSin texto completo-
item.grantfulltextnone-
crisitem.author.deptGIR IUNAT: Control analítico de fuentes medioambientales-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Ingeniería de Procesos-
crisitem.author.deptGIR IUNAT: Control analítico de fuentes medioambientales-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Ingeniería de Procesos-
crisitem.author.orcid0000-0003-2284-8400-
crisitem.author.orcid0000-0001-5759-4469-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.fullNameLeón Zerpa, Federico Antonio-
crisitem.author.fullNameRamos Martín, Alejandro-
Appears in Collections:Artículos
Show simple item record

Page view(s)

66
checked on May 11, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.