dc.description.abstractDepending on the properties required for the medical instruments, compared with the classical materials, the high-entropy alloys (HEAs) are a versatile option. Electrochemical Impedance Spectroscopy (EIS) measurements have been performed on AlxCoCrFeNi-type high-entropy alloys with various concentrations of Al content (x = 0.6, 0.8, and 1.0) in order to characterize their passive film and corrosion resistance at 37◦C under infectious simulated physiological conditions (Ringer´s solution acidulated with HCl) at pH = 3. The impedance spectra were obtained at different potential values between −0.7 and +0.7 V vs. SCE. Analysis of the impedance spectra was carried out by fitting different equivalent circuits to the experimental data. Two equivalent circuits, with one time constant and two time constants respectively, can be satisfactorily used for fitting the spectra: one time constant represents the characteristics of the compact passive film, and the second one is for the porous passive film. With the decreasing of Al content, the obtained EIS results are correlated with the evolution of the microhardness and microstructure, which is characterized by Optical Microscopy (OM), Scanning Electron Microscopy (SEM), and Energy-Dispersive X-Ray Spectroscopy (EDAX). It can be observed for all alloys that the resistance of the passive film is very high and decreases with the potential: the very high resistance of the passive film implies a high corrosion resistance, which can be assigned to the formation of the protective oxide layer and demonstrates that the analyzed alloys fulfill the prerequisites for their use as new materials for the manufacturing of medical instruments.en_US
dc.languageengen_US
dc.relation.ispartofBiology of metalsen_US
dc.sourceMetals [EISSN 2075-4701], v. 11 (6), (Junio 2021)en_US
dc.subject331110 Instrumentos médicosen_US
dc.subject3311 tecnología de la instrumentaciónen_US
dc.subject.otherAluminumen_US
dc.subject.otherCorrosion Resistanceen_US
dc.subject.otherElectrochemical Impedance Spectroscopy (EIS)en_US
dc.subject.otherEquivalent Circuiten_US
dc.subject.otherHigh-Entropy Alloysen_US
dc.subject.otherPassivationen_US
dc.subject.otherRinger Solutionen_US
dc.titleComparative eis study of alxcocrfeni alloys in ringer’s solution for medical instrumentsen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.3390/met11060928en_US
dc.identifier.scopus85107264520-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.authorscopusid57196010052-
dc.contributor.authorscopusid57224225438-
dc.contributor.authorscopusid18435025300-
dc.contributor.authorscopusid6602582214-
dc.identifier.eissn2075-4701-
dc.identifier.issue6-
dc.relation.volume11en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.description.notasThis article belongs to the Special Issue Corrosion without Limit: From Past to Futureen_US
dc.utils.revisionen_US
dc.date.coverdateJunio 2021en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-INGen_US
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptGIR Nanomaterials and Corrosion-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.deptGIR SIANI: Mecánica de los Medios Continuos y Estructuras-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptDepartamento de Ingeniería Civil-
crisitem.author.deptGIR Nanomaterials and Corrosion-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.orcid0000-0002-1824-6792-
crisitem.author.orcid0000-0003-0623-3318-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.fullNameSocorro Perdomo, Pedro Pablo-
crisitem.author.fullNameFlorido Suárez, Néstor Rubén-
crisitem.author.fullNameMirza Rosca, Julia Claudia-
Appears in Collections:Artículos
Adobe PDF (1,32 MB)
Show simple item record

SCOPUSTM   
Citations

28
checked on Mar 30, 2025

WEB OF SCIENCETM
Citations

26
checked on Mar 30, 2025

Page view(s)

125
checked on Nov 16, 2024

Download(s)

199
checked on Nov 16, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.