Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/110305
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Villa, Enrique | en_US |
dc.contributor.author | Aja, Beatriz | en_US |
dc.contributor.author | de la Fuente, Luisa | en_US |
dc.contributor.author | Artal, Eduardo | en_US |
dc.contributor.author | Arteaga-Marrero, Natalia | en_US |
dc.contributor.author | González-Pérez, Sara | en_US |
dc.contributor.author | Ruiz Alzola, Juan | en_US |
dc.date.accessioned | 2021-07-08T09:16:35Z | - |
dc.date.available | 2021-07-08T09:16:35Z | - |
dc.date.issued | 2021 | en_US |
dc.identifier.issn | 2079-9292 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/110305 | - |
dc.description.abstract | A new configuration of a pseudo-correlation type radiometer is proposed for a microwave biomedical application, such as diabetic foot neuropathy. The new approach as well as its simulated performance are thoroughly assessed using commercial off-the-shelf components and custom designed subsystems. We configured a pseudo-correlation receiver, centred at 3.5 GHz, to validate the proposal, comparing its simulated response with a measured alternative based on a 90◦ hybrid coupler pseudo-correlation prototype. We custom designed a balanced Wilkinson power divider and a 180◦ hybrid coupler to fulfil the receiver’s requirements. The proposed configuration demonstrated an improved noise temperature response. The main advantage is to enable the recalibration of the receiver through simultaneous measurable output signals, proportional to each input signal, as well as the correlated response between them. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Electronics (Switzerland) | en_US |
dc.source | Electronics (Switzerland) [EISSN 2079-9292], v. 10 (12), 1427, (Junio 2021) | en_US |
dc.subject | 3314 Tecnología médica | en_US |
dc.subject.other | Biomedical Applications | en_US |
dc.subject.other | Microwave Radiometry | en_US |
dc.subject.other | Pseudo-Correlation Radiometer | en_US |
dc.subject.other | Receiver Configuration | en_US |
dc.title | Analysis and performance assessment of a real-time correction pseudo-correlation microwave radiometer for medical applications | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/electronics10121427 | en_US |
dc.identifier.scopus | 85107726841 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.authorscopusid | 26325126700 | - |
dc.contributor.authorscopusid | 8695569400 | - |
dc.contributor.authorscopusid | 8695568500 | - |
dc.contributor.authorscopusid | 6603673927 | - |
dc.contributor.authorscopusid | 14038607600 | - |
dc.contributor.authorscopusid | 55945783000 | - |
dc.contributor.authorscopusid | 56614041800 | - |
dc.identifier.eissn | 2079-9292 | - |
dc.identifier.issue | 12 | - |
dc.relation.volume | 10 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.description.notas | This article belongs to the Special Issue Analysis and Test of Microwave Circuits and Subsystems | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Junio 2021 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-TEL | en_US |
dc.description.sjr | 0,59 | |
dc.description.jcr | 2,69 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q3 | |
dc.description.scie | SCIE | |
dc.description.miaricds | 10,5 | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.orcid | 0000-0002-3545-2328 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Ruiz Alzola, Juan Bautista | - |
Colección: | Artículos |