Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/108028
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zander, Tobias | en_US |
dc.contributor.author | García, Giovanni | en_US |
dc.contributor.author | Concepción, Yamileth | en_US |
dc.contributor.author | Parra, Felipe | en_US |
dc.contributor.author | Valdés, Michel | en_US |
dc.contributor.author | Maynar Moliner, Manuel | en_US |
dc.date.accessioned | 2021-06-28T13:49:16Z | - |
dc.date.available | 2021-06-28T13:49:16Z | - |
dc.date.issued | 2021 | en_US |
dc.identifier.issn | 1526-6028 | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | http://hdl.handle.net/10553/108028 | - |
dc.description.abstract | Purpose: To present a bailout technique for bridging covered stent placement during branched endovascular aortic repair (BEVAR) in complex anatomy. Technique: BEVAR is an alternative technique for the treatment of thoracoabdominal aortic aneurysms (TAAAs). Visceral and renal vessels must be preserved by bridging covered stent placement through downward-oriented branches of the main stent graft device. Challenging anatomy such as kinking and elongation of the aorta, or type III aortic arch configuration may impede successful catheterization of these branches due to reduced steerability and pushability of the endovascular material. Different alternative techniques have been described to overcome these anatomic barriers. This technical note adds another endovascular solution to complex cases using the guiding sheath stabilizing technique. It is based on a standard “through-and-through” technique. An attached snare is inserted via femoral approach, providing a stable position for branch catheterization and bridging covered stent deployment. Conclusion: The stabilizing technique is safe and easy to perform and provides a stable position of the guiding sheath when antegrade branch catheterization is challenging. This technique is an additional tool for handling challenging cases. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Endovascular Therapy | en_US |
dc.source | Journal of Endovascular Therapy [ISSN 1526-6028], v. 28(5), p. 687-691 | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 321307 Cirugía del corazón | en_US |
dc.subject | 320501 Cardiología | en_US |
dc.subject.other | Bailout Technique | en_US |
dc.subject.other | Branched Endovascular Aortic Repair | en_US |
dc.subject.other | Bridging Covered Stent | en_US |
dc.subject.other | Catheterization | en_US |
dc.subject.other | Snare | en_US |
dc.subject.other | Target Vessel | en_US |
dc.subject.other | Thoracoabdominal Aortic Aneurysm | en_US |
dc.title | Stabilizing Technique for Bridging Stent Placement in Branched Endovascular Aortic Repair | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1177/15266028211025025 | en_US |
dc.identifier.scopus | 85108240986 | - |
dc.contributor.orcid | 0000-0002-4816-4026 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.authorscopusid | 24537953400 | - |
dc.contributor.authorscopusid | 57224735579 | - |
dc.contributor.authorscopusid | 57224725734 | - |
dc.contributor.authorscopusid | 57224729604 | - |
dc.contributor.authorscopusid | 56437325700 | - |
dc.contributor.authorscopusid | 7005962555 | - |
dc.identifier.eissn | 1545-1550 | - |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 5 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Enero 2021 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.sjr | 1,201 | |
dc.description.jcr | 3,089 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
dc.description.miaricds | 10,9 | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUIBS: Tecnología Médica y Audiovisual | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.orcid | 0000-0001-9154-0712 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Maynar Moliner,Manuel | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
1
checked on Nov 24, 2024
WEB OF SCIENCETM
Citations
1
checked on Nov 24, 2024
Page view(s)
93
checked on Aug 31, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.