Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/107225
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Fiorucci, Maria Paula | en_US |
dc.contributor.author | Cuadrado Hernández, Alberto Javier | en_US |
dc.contributor.author | Yánez Santana, Manuel Alejandro | en_US |
dc.contributor.author | Martel Fuentes, Oscar | en_US |
dc.contributor.author | Mentado, Belinda | en_US |
dc.contributor.author | Monopoli, Donato | en_US |
dc.date.accessioned | 2021-05-17T08:56:37Z | - |
dc.date.available | 2021-05-17T08:56:37Z | - |
dc.date.issued | 2021 | en_US |
dc.identifier.issn | 0264-1275 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/107225 | - |
dc.description.abstract | Large thoracic defects need to be reconstructed to restore inner organs protection and normal ventilation. Early rigid implants have provided the stabilization of the ribcage; however, those have been associated with breathing restrictions. The evolution of additive manufacturing has enabled the production of 3D custom-made thoracic implants. This has led to case reports on reconstructions with these prostheses, particularly for large anterior resections. A novel design of thoracic implant with dynamic capacity has already been reported, with promising short-term outcomes. However, specific biomechanical studies are needed to clarify its mechanical behaviour. A study of the evolution of the design of dynamic thoracic implants was carried out and such implants were biomechanically tested. Furthermore, finite element analyses were carried out to obtain a simple and reliable model to predict the implant behaviour, considering a rib and its costal cartilage. In the models, the stiffness and stress distribution along the implant and the bone showed that the reconstructions exhibited adequate mechanical behaviour. One of the designs provided a flexibility that closely matched the native model and the maximum stress values did not exceed the 30% of the yield strength of Ti-6Al-4V. The implants strength was demonstrated to be sufficient under tested conditions. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Materials and Design | en_US |
dc.source | Materials and Design [ISSN 0264-1275], v. 206, 109758, (Agosto 2021) | en_US |
dc.subject | 3314 Tecnología médica | en_US |
dc.subject | 331402 Prótesis | en_US |
dc.subject.other | Custom-made dynamic implant | en_US |
dc.subject.other | Electron Beam Melting | en_US |
dc.subject.other | Biomechanical analysis | en_US |
dc.subject.other | Ti-6Al-4V | en_US |
dc.subject.other | Chest wall reconstruction | en_US |
dc.title | Biomechanical characterization of custom-made dynamic implants fabricated by Electron Beam Melting for anterior chest wall reconstruction | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1016/j.matdes.2021.109758 | en_US |
dc.identifier.isi | 000665498700029 | - |
dc.identifier.isi | 000670309700003 | - |
dc.identifier.eissn | 1873-4197 | - |
dc.relation.volume | 206 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 1712677 | - |
dc.contributor.daisngid | 44530002 | - |
dc.contributor.daisngid | 42320569 | - |
dc.contributor.daisngid | 44468050 | - |
dc.contributor.daisngid | 44502408 | - |
dc.contributor.daisngid | 44424045 | - |
dc.description.observaciones | The authors also acknowledge the Postdoctoral Program grant provided by the University of Las Palmas de Gran Canaria, Spain. | en_US |
dc.description.numberofpages | 9 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Fiorucci, MP | - |
dc.contributor.wosstandard | WOS:Cuadrado, A | - |
dc.contributor.wosstandard | WOS:Yanez, A | - |
dc.contributor.wosstandard | WOS:Martel, O | - |
dc.contributor.wosstandard | WOS:Mentado, B | - |
dc.contributor.wosstandard | WOS:Monopoli, D | - |
dc.date.coverdate | Agosto 2021 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-ING | en_US |
dc.description.sjr | 1,802 | |
dc.description.jcr | 9,417 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
dc.description.miaricds | 11,0 | |
item.fulltext | Con texto completo | - |
item.grantfulltext | open | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.orcid | 0000-0002-4532-7520 | - |
crisitem.author.orcid | 0000-0002-8599-781X | - |
crisitem.author.orcid | 0000-0002-1736-552X | - |
crisitem.author.orcid | 0000-0003-3806-5523 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Fiorucci,Maria Paula | - |
crisitem.author.fullName | Cuadrado Hernández, Alberto Javier | - |
crisitem.author.fullName | Yánez Santana, Manuel Alejandro | - |
crisitem.author.fullName | Martel Fuentes, Oscar | - |
Appears in Collections: | Artículos |
WEB OF SCIENCETM
Citations
7
checked on Mar 30, 2025
Page view(s)
225
checked on Nov 23, 2024
Download(s)
179
checked on Nov 23, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.