Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/106954
Título: | Optimized design method for storage systems in photovoltaic plants with delivery limitation | Autores/as: | Colmenar-Santos, Antonio Monteagudo-Mencucci, Mario Rosales Asensio, Enrique de Simón-Martín, Miguel Pérez-Molina, Clara |
Clasificación UNESCO: | 332205 Fuentes no convencionales de energía | Palabras clave: | Renewable energy storage Photovoltaic solar energy System optimization Battery capacity |
Fecha de publicación: | 2019 | Publicación seriada: | Solar Energy | Resumen: | It results widely common for distribution network operators to impose restrictions on delivered solar photovoltaic generated power when the power plant rated power is greater than the maximum allowed due to the distribution network capacity. Thus, a feasible solution to maximize the performance of the solar power plant is the integration of battery energy storage systems. Although this configuration has been extensively studied in the existing literature, an optimal design method to determine the proper size and operation of the energy storage system needs to be developed. In this paper, a novel method to help power plants designers to determine the optimal battery energy storage capacity to integrate into any solar photovoltaic power plant is provided. The proposed algorithm minimizes the potential power curtailment and optimizes the utilization rate of the batteries storage system. The algorithm can be applied to any grid connected solar photovoltaic power plant under delivery power restrictions, regardless of power capacity and location. The algorithm has been implemented to a simulated power plant with delivery limitations based in a real case, and results with the optimal battery capacity show that the system would be able to recover up to the 83% of the curtailed energy and a yearly average capacity utilization of 56%. Moreover, the BESS operation has been validated with a scaled model run in Simulink and laboratory measurements, achieving 98% of curtailed energy recovery rate and a 57% of average capacity utilization. | URI: | http://hdl.handle.net/10553/106954 | ISSN: | 0038-092X | DOI: | 10.1016/j.solener.2019.01.046 | Fuente: | Solar Energy [ISSN 0038-092X], n. 180, p. 468-488 (marzo 2019) |
Colección: | Artículos |
Citas de WEB OF SCIENCETM
Citations
13
actualizado el 22-dic-2024
Visitas
81
actualizado el 01-jun-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.