Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/105855
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chico, Ana | en_US |
dc.contributor.author | Aguilera, Eva | en_US |
dc.contributor.author | Ampudia-Blasco, Francisco Javier | en_US |
dc.contributor.author | Bellido, Virgina | en_US |
dc.contributor.author | Cardona-Hernández, Roque | en_US |
dc.contributor.author | Escalada, Francisco Javier | en_US |
dc.contributor.author | Fernández, Diego | en_US |
dc.contributor.author | Gómez-Peralta, Fernando | en_US |
dc.contributor.author | González Pérez de Villar, Noemí | en_US |
dc.contributor.author | Gorgojo, Juan José | en_US |
dc.contributor.author | Mezquita-Raya, Pedro | en_US |
dc.contributor.author | Morales, Cristóbal | en_US |
dc.contributor.author | De Pablos Velasco, Pedro Luis | en_US |
dc.contributor.author | Palomares, Rafael | en_US |
dc.contributor.author | Parra, Juan | en_US |
dc.contributor.author | Rivero, María Teresa | en_US |
dc.contributor.author | González-Blanco, Cintia | en_US |
dc.date.accessioned | 2021-03-17T14:12:45Z | - |
dc.date.available | 2021-03-17T14:12:45Z | - |
dc.date.issued | 2019 | en_US |
dc.identifier.issn | 1932-2968 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/105855 | - |
dc.description.abstract | The flash glucose monitoring (FGM) system FreeStyle Libre® is a device that measures interstitial glucose in a very simple way and indicates direction and speed of glucose change. This allows persons with diabetes to prevent hypoglycemic and hyperglycemic events. Scientific evidence indicates that the system can improve glycemic control and quality of life. To obtain the maximum benefit, it is necessary to properly handle glucose values and trends. Due to the generalization of the system use, the purpose of the document is to provide recommendations for the optimal use of the device, not only in the management of glucose values and trends but also in the prevention of hypoglycemia, actuation in exercise, special situations, and retrospective analysis of the glucose data, among others. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of diabetes science and technology | en_US |
dc.source | Journal of diabetes science and technology [1932-2968], v. 14(1), p. 155-164 | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 320502 Endocrinología | en_US |
dc.subject.other | Ambulatory glucose profile | en_US |
dc.subject.other | Flash glucose monitoring | en_US |
dc.subject.other | Interstitial glucose | en_US |
dc.subject.other | Type 1 diabetes | en_US |
dc.subject.other | Type 2 diabetes | en_US |
dc.title | Clinical Approach to Flash Glucose Monitoring: An Expert Recommendation | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.identifier.doi | 10.1177/1932296819841911 | en_US |
dc.description.lastpage | 164 | en_US |
dc.identifier.issue | 1 | - |
dc.description.firstpage | 155 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 10 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Mayo 2020 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.sjr | 0,946 | |
dc.description.sjrq | Q1 | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR IUIBS: Rendimiento humano, ejercicio físico y salud | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0002-9190-2581 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | De Pablos Velasco, Pedro Luis | - |
Appears in Collections: | Artículos |
WEB OF SCIENCETM
Citations
16
checked on Nov 17, 2024
Page view(s)
124
checked on Jul 13, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.