Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/77654
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Falcon Gonzalez, Juan Carlos | en_US |
dc.contributor.author | Borkoski Barreiro, Silvia | en_US |
dc.contributor.author | Ramos De Miguel, Ángel | en_US |
dc.contributor.author | Ramos Macías, Ángel Manuel | en_US |
dc.date.accessioned | 2021-02-10T14:49:39Z | - |
dc.date.available | 2021-02-10T14:49:39Z | - |
dc.date.issued | 2019 | en_US |
dc.identifier.issn | 1827-675X | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/77654 | - |
dc.description.abstract | The objective of this study is the evaluation of speech recognition of experienced CI recipients with standard MAP settings using the default frequency-allocation tables with the optimised frequency-allocation MAP. This is an observational, cross-sectional and quantitative-approach study on 50 adult cochlear implant recipients, 20 bilateral and 30 unilateral implant recipients. 23 men (46%) and 27 women (54%). All subjects were ≥ 18 years old. Differences between the means of the thresholds in tone audiometry in free fields were statistically significant in both unilaterally and bilaterally implanted patients; similar results were obtained between average benefits in disyllabic for both unilaterally and bilaterally implanted patients (p < 0.005). The differences between the means of scores were statistically significant for unilaterally and bilaterally implanted patients, similarly occurred with the average in HINT test between standard SRT50% programming and frequency allocation fitting (p < 0.005). Patients using the frequency allocation method, which assigns frequencies based on fundamental frequencies, showed better perception of disyllabic words and open-set sentences in quiet and in noise than patients previously fitted with standard fitting techniques. The method can be applied to different processors and used with different strategies of stimulation. It allows reduction of current intensity levels as well as an increase in the dynamic range and improves the quality of the representation of the signal. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Acta Otorhinolaryngologica Italica | en_US |
dc.source | Acta Otorhinolaryngologica Italica [ISSN 1827-675X], v. 39(3) | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 120601 Construcción de algoritmos | en_US |
dc.subject | 220103 Física de la audición | en_US |
dc.subject | 220199 Otras (especificar) | en_US |
dc.subject.other | Implantes cocleares | en_US |
dc.subject.other | Percepción del habla | en_US |
dc.subject.other | Métodos de programación | en_US |
dc.title | Improvement of speech perception in noise and quiet using a customised Frequency-Allocation Programming (FAP) method | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.14639/0392-100X-2013 | en_US |
dc.description.lastpage | 185 | en_US |
dc.identifier.issue | 3 | - |
dc.description.firstpage | 178 | en_US |
dc.relation.volume | 39 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.investigacion | Ciencias | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 8 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Mayo 2019 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.sjr | 0,765 | |
dc.description.jcr | 1,51 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q3 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | GIR SIANI: Modelización y Simulación Computacional | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Informática y Sistemas | - |
crisitem.author.dept | GIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0002-5743-4374 | - |
crisitem.author.orcid | 0000-0002-0528-815X | - |
crisitem.author.orcid | 0000-0002-4709-5559 | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.fullName | Falcon Gonzalez,Juan Carlos | - |
crisitem.author.fullName | Borkoski Barreiro,Silvia | - |
crisitem.author.fullName | Ramos De Miguel, Ángel | - |
crisitem.author.fullName | Ramos Macías, Ángel Manuel | - |
Colección: | Artículos |
Citas de WEB OF SCIENCETM
Citations
2
actualizado el 24-nov-2024
Visitas
146
actualizado el 28-sep-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.