Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/76986
Title: | Test of a processing algorithm for NIR laser diodes based pulse oximetry | Authors: | López Silva, Sonnia María Silveira, Juan Pedro Dotor, María Luisa |
UNESCO Clasification: | 3311 tecnología de la instrumentación | Keywords: | Biomedical Signal Processing Pulse Oximetry Photoplethysmography Laser Diodes Near Infrared |
Issue Date: | 2003 | Journal: | Proceedings of SPIE - The International Society for Optical Engineering | Conference: | Conference on Bioengineered and Bioinspired Systems | Abstract: | Pulse oximeters are used for the non-invasive monitoring of arterial blood haemoglobin oxygen saturation. The photoplethysmographic (PPG) signals measured at two specific wavelengths are decomposed into its variable (E-AC) and the constant component (E-DC) for deriving a parameter related to the arterial blood oxygen saturation (So(2)) Previously it has been reported a signal processing algorithm for a near infrared (NIR) laser diodes based transmittance pulse oximetry system. The proposed algorithm permits the numeric separation of the variable and constant parts of the signals for two wavelengths, to derive a quotient (q) proportional to the So(2) levels. The E-DC is obtained by a low pass filtering and E-AC by a pass-band one, followed by a non-linear filtering. The non-linear filter is based on the reduction of the E-AC peak-to-peak frequency distribution for the analyzed time interval (histogram reduction). In the present study is exposed the influence of Bessel filters cut-off frequencies and histogram reduction percentage on q values. The test has been conducted on PPG signals recorded through experimental studies on human healthy volunteers using the NIR laser diodes based transmittance pulse oximetry system. The sources of artefacts and noise in the laser diodes PPG signals are discussed. | URI: | http://hdl.handle.net/10553/76986 | ISBN: | 0-8194-4979-2 | ISSN: | 0277-786X | DOI: | 10.1117/12.499067 | Source: | Bioengineered and Bioinspired Systems [ISSN 0277-786X], v. 5119, p. 178-188, (2003) |
Appears in Collections: | Actas de congresos |
Page view(s)
64
checked on May 4, 2024
Download(s)
78
checked on May 4, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.