Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/76690
Title: | Hot gas filtration using a moving bed heat exchanger-filter (MHEF) | Authors: | Henríquez, V. Macías Machín, A. |
Keywords: | Gas Filtration Granular Filter Heat Exchanger |
Issue Date: | 1997 | Journal: | Chemical Engineering and Processing: Process Intensification | Abstract: | A study was conducted on the use of a Moving Bed Heat Exchanger-Filter (MHEF) for removing fine dust particles from gases. The influence of a number of variables was examined, including gas velocities, solid velocities, gas temperatures and dust sizes. The collection efficiency was found to decrease with increasing temperature; the total collection efficiency decreases strongly when the solid velocity increases. A stable numerical model for filtration and heat exchange was developed that predicts the two dimensional transient response of both solid and fluid phases. The numerical model incorporates variation in void fraction, velocities and transport coefficient due to combined processes of filtration and heat exchange. | URI: | http://hdl.handle.net/10553/76690 | ISSN: | 0255-2701 | DOI: | 10.1016/S0255-2701(97)00017-2 | Source: | Chemical Engineering and Processing: Process Intensification [ISSN 0255-2701], v. 36 (5), p. 353-361, (Septiembre 1997) |
Appears in Collections: | Artículos |
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.