Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/76686
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Pan, Manuel | en_US |
dc.contributor.author | Suárez de Lezo, José | en_US |
dc.contributor.author | Medina, Alfonso | en_US |
dc.contributor.author | Romero, Miguel | en_US |
dc.contributor.author | Hernández, Enrique | en_US |
dc.contributor.author | Segura, José | en_US |
dc.contributor.author | Melián, Francisco | en_US |
dc.contributor.author | Wangüemert, Fernando | en_US |
dc.contributor.author | Landin, Manuel | en_US |
dc.contributor.author | Benítez, Fernando | en_US |
dc.contributor.author | Amat, Manuel | en_US |
dc.contributor.author | Velasco, Francisco | en_US |
dc.contributor.author | Torres, Antonio | en_US |
dc.date.accessioned | 2020-12-15T12:12:23Z | - |
dc.date.available | 2020-12-15T12:12:23Z | - |
dc.date.issued | 1997 | en_US |
dc.identifier.issn | 0002-9149 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/76686 | - |
dc.description.abstract | After coronary stent implantation, antithrombotic therapy is required; however, the specific drug combination to use is still under debate.(1) The ideal regimen should avoid subacute stent thrombosis and hemorrhagic complications and allow an early hospital discharge. The purpose of this study is the evaluation of the safety and efficiency of neutralizing circulating heparin with protamine administration immediately after coronary stent implantation. We hypothesized that the in-laboratory removal of the femoral sheath could reduce groin complications and would shorten the postprocedural period of bed rest and hospital stay after stent implantation. To test this hypothesis, our study compares, in a randomized way, the hospital course of patients with early sheath removal after protamine administration with those in which the femoral sheath was removed after the complete spontaneous disappearance of heparin activity. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | The American journal of cardiology | en_US |
dc.source | The American journal of cardiology [ISSN 0002-9149], v. 80 (10), p. 1336-8, (Noviembre 1997) | en_US |
dc.subject | 320501 Cardiología | en_US |
dc.subject.other | Venous Bypass Grafts | en_US |
dc.subject.other | Coronary Angioplasty | en_US |
dc.subject.other | Ultrasound Guidance | en_US |
dc.subject.other | Therapy | en_US |
dc.subject.other | Anticoagulation | en_US |
dc.subject.other | Antiplatelet | en_US |
dc.title | In-laboratory removal of femoral sheath following protamine administration in patients having intracoronary stent implantation | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/s0002-9149(97)00676-0 | en_US |
dc.identifier.pmid | 9388109 | - |
dc.identifier.isi | A1997YG63500015 | - |
dc.description.lastpage | 1338 | en_US |
dc.identifier.issue | 10 | - |
dc.description.firstpage | 1336 | en_US |
dc.relation.volume | 80 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 77557 | - |
dc.contributor.daisngid | 67522 | - |
dc.contributor.daisngid | 5831803 | - |
dc.contributor.daisngid | 156230 | - |
dc.contributor.daisngid | 2740671 | - |
dc.contributor.daisngid | 1825688 | - |
dc.contributor.daisngid | 4882689 | - |
dc.contributor.daisngid | 3466905 | - |
dc.contributor.daisngid | 16461428 | - |
dc.contributor.daisngid | 10640467 | - |
dc.contributor.daisngid | 9227558 | - |
dc.contributor.daisngid | 5298529 | - |
dc.contributor.daisngid | 50528 | - |
dc.description.numberofpages | 4 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Pan, M | - |
dc.contributor.wosstandard | WOS:deLezo, JS | - |
dc.contributor.wosstandard | WOS:Medina, A | - |
dc.contributor.wosstandard | WOS:Romero, M | - |
dc.contributor.wosstandard | WOS:Hernandez, E | - |
dc.contributor.wosstandard | WOS:Segura, J | - |
dc.contributor.wosstandard | WOS:Melian, F | - |
dc.contributor.wosstandard | WOS:Wanguemert, F | - |
dc.contributor.wosstandard | WOS:Landin, M | - |
dc.contributor.wosstandard | WOS:Benitez, F | - |
dc.contributor.wosstandard | WOS:Amat, M | - |
dc.contributor.wosstandard | WOS:Velasco, F | - |
dc.contributor.wosstandard | WOS:Torres, A | - |
dc.date.coverdate | Noviembre 1997 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.description.jcr | 2,402 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
Colección: | Artículos |
Citas de WEB OF SCIENCETM
Citations
64
actualizado el 30-mar-2025
Visitas
72
actualizado el 16-sep-2023
Descargas
152
actualizado el 16-sep-2023
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.