Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/76584
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Garcés Martín, Gerardo | en_US |
dc.contributor.author | Perdomo, E. | en_US |
dc.contributor.author | Guerra, A. | en_US |
dc.contributor.author | Cabrera-Bonilla, R. | en_US |
dc.date.accessioned | 2020-12-11T18:09:53Z | - |
dc.date.available | 2020-12-11T18:09:53Z | - |
dc.date.issued | 1995 | en_US |
dc.identifier.issn | 0341-2695 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/76584 | - |
dc.description.abstract | A prospective study was carried out to test the sensitivity and specificity of stress radiography in detecting anterior cruciate ligament deficiency in both knees of 116 patients using the Telos device. lit 47 of these a total or partial rupture of the anterior cruciate ligament was diagnosed by arthroscopy, while the ligament was intact in the remaining 69 patients. The mean difference in radiological translation between the injured and the normal knee was greater than 5 mm (p <0.001) in those with anterior cruciate deficiency, and less than 3 mm in the others. A differential displacement of lip to 3 mm was considered normal. The sensitivity of the method was less than 67% and the specificity was 100%. Clinical diagnosis had a sensitivity of 70.2% and a specificity of 98.5%. Our findings suggest that, although a differential translation of more than 3 mm can be diagnostic, smaller differences do not rule out anterior cruciate deficiency. | en_US |
dc.description.abstract | Les auteurs ont réalisé une étude prospective pour évaluer la sensibilité et la spécificité des radiographies en position forcée dans le diagnostic des insuffisances du ligament croisé antérieur (LCA). Une radiographie en tiroir forcé des deux genoux a d'abord été faite, en utilisant l'appareil Telos, chez 116 patients devant subir une arthroscopie unilatérale. Chez 47 de ces patients une rupture totale ou partielle du LCA a été confirmée par arthroscopie, qui a montrée un ligament intact chez les 69 autres. La différence moyenne de translation entre le genou blessé et le genou sain a été supérieure à 5 mm (p<0.001) chez les patients ayant une insuffisance du LCA et inférieure à 3 mm chez les autres (une différence de 3 mm a été considérée comme normale). La sensibilité de la méthode a été de moins de 67% et le spécificité de 100%. L'examen clinique a une sensibilité de 70.2% et une spécificité de 98.5%. Ces résultats permettent de penser que, bien qu'une translation supérieure à 3 mm puisse avoir une valeur diagnostique, une moindre différence n'exclut pas une insuffisance du ligament croisé antérieur. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | International Orthopaedics | en_US |
dc.source | International Orthopaedics [ISSN 0341-2695], v. 19 (2), p. 86-88, (Abril 1995) | en_US |
dc.subject | 321315 Traumatología | en_US |
dc.subject.other | Public Health | en_US |
dc.subject.other | Anterior Cruciate Ligament | en_US |
dc.subject.other | Small Difference | en_US |
dc.subject.other | Clinical Diagnosis | en_US |
dc.subject.other | Cruciate Ligament | en_US |
dc.title | Stress radiography in the diagnosis of anterior cruciate ligament deficiency | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1007/BF00179966 | en_US |
dc.identifier.scopus | 0029014291 | - |
dc.identifier.isi | A1995QW79300008 | - |
dc.contributor.authorscopusid | 56406565300 | - |
dc.contributor.authorscopusid | 16408283800 | - |
dc.contributor.authorscopusid | 57196671604 | - |
dc.contributor.authorscopusid | 6503989183 | - |
dc.description.lastpage | 88 | en_US |
dc.identifier.issue | 2 | - |
dc.description.firstpage | 86 | en_US |
dc.relation.volume | 19 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 34942581 | - |
dc.contributor.daisngid | 7027532 | - |
dc.contributor.daisngid | 20835816 | - |
dc.contributor.daisngid | 18780519 | - |
dc.description.numberofpages | 3 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:GARCES, GL | - |
dc.contributor.wosstandard | WOS:PERDOMO, E | - |
dc.contributor.wosstandard | WOS:GUERRA, A | - |
dc.contributor.wosstandard | WOS:CABRERABONILLA, R | - |
dc.date.coverdate | Abril 1995 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.description.scie | SCIE | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0003-4494-9077 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Garcés Martín, Gerardo | - |
Colección: | Artículos |
Citas SCOPUSTM
29
actualizado el 29-dic-2024
Citas de WEB OF SCIENCETM
Citations
21
actualizado el 25-feb-2024
Visitas
125
actualizado el 23-may-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.