dc.description.abstract | Purpose: To report a case of intimal dehiscence associated with endovascular intervention in patients with aortic dissection.Case Report. A 65-year-old man presented with a type B dissection extending to the level of the common iliac arteries. Two Talent stent-grafts were placed in the descending thoracic aorta to close the entry point, but 2 lumens remained. Three days later, abdominal pain prompted another imaging session, which demonstrated a large cylindrical filling defect in the abdominal aorta ("tube-in-tube") assumed to be a partially or completely dehisced intima. Fenestration marginally improved flow to the visceral vessels, and the patient improved clinically. However, 4 days later, recurrent ischemic symptoms prompted surgery; a complete dehiscence of the aortic intima starting at the descending aorta extended to the distal abdominal aorta. The aorta was resected, but the patient died from disseminated intravascular coagulation.Conclusions: Intimal flap dehiscence associated with an endovascular procedure in the management of aortic dissection is an uncommon complication. Early detection and prompt surgical intervention of such a complication could save the patient's life. Endovascular procedures are unlikely to resolve the hemodynamic problem caused by a dehisced, distally migrated, collapsed intima. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Endovascular Therapy | en_US |
dc.source | Journal Of Endovascular Therapy [ISSN 1526-6028], v. 12 (1), p. 103-109, (Febrero 2005) | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 320501 Cardiología | en_US |
dc.subject.other | Intimointimal Intussusception | en_US |
dc.subject.other | Circumferential Dissection | en_US |
dc.subject.other | Unusual Complication | en_US |
dc.subject.other | Ct Diagnosis | en_US |
dc.subject.other | Tear | en_US |
dc.subject.other | Thoracic Aorta | en_US |
dc.subject.other | Abdominal Aorta | en_US |
dc.subject.other | Type B Dissection | en_US |
dc.subject.other | Endovascular Repair | en_US |
dc.subject.other | Stent-Graft | en_US |
dc.subject.other | Complication | en_US |
dc.subject.other | Intimal Dehiscence | en_US |
dc.title | Intimal dehiscence in the abdominal aorta following balloon fenestration for type B dissection | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1583/04-1368.1 | en_US |
dc.identifier.scopus | 13644271372 | - |
dc.identifier.isi | 000226954100016 | - |
dc.contributor.authorscopusid | 7005962555 | - |
dc.contributor.authorscopusid | 6603053476 | - |
dc.contributor.authorscopusid | 24537953400 | - |
dc.contributor.authorscopusid | 57195594774 | - |
dc.contributor.authorscopusid | 7006542164 | - |
dc.contributor.authorscopusid | 16641392900 | - |
dc.contributor.authorscopusid | 7101832612 | - |
dc.identifier.eissn | 1545-1550 | - |
dc.description.lastpage | 109 | en_US |
dc.identifier.issue | 1 | - |
dc.description.firstpage | 103 | en_US |
dc.relation.volume | 12 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 23221678 | - |
dc.contributor.daisngid | 4778533 | - |
dc.contributor.daisngid | 94228 | - |
dc.contributor.daisngid | 20278976 | - |
dc.contributor.daisngid | 28135379 | - |
dc.contributor.daisngid | 3875761 | - |
dc.contributor.daisngid | 1827169 | - |
dc.description.numberofpages | 7 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Maynar, M | - |
dc.contributor.wosstandard | WOS:Rostagno, R | - |
dc.contributor.wosstandard | WOS:Zander, T | - |
dc.contributor.wosstandard | WOS:Qian, Z | - |
dc.contributor.wosstandard | WOS:Llorens, R | - |
dc.contributor.wosstandard | WOS:Zerolo, I | - |
dc.contributor.wosstandard | WOS:Castaneda, WR | - |
dc.date.coverdate | Febrero 2005 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.jcr | 1,805 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUIBS: Tecnología Médica y Audiovisual | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.orcid | 0000-0001-9154-0712 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Maynar Moliner,Manuel | - |
Colección: | Artículos |
Citas SCOPUSTM
7
actualizado el 15-dic-2024
Citas de WEB OF SCIENCETM
Citations
7
actualizado el 15-dic-2024
Visitas
138
actualizado el 07-dic-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.