Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/73933
Campo DC Valoridioma
dc.contributor.authorPan, Manuelen_US
dc.contributor.authorMedina, Alfonsoen_US
dc.contributor.authorSuárez de Lezo, Joséen_US
dc.contributor.authorRomero Moreno, Miguel Ángelen_US
dc.contributor.authorMelián, Franciscoen_US
dc.contributor.authorPavlovic, Djordjeen_US
dc.contributor.authorHernández, Enriqueen_US
dc.contributor.authorSegura, Joséen_US
dc.contributor.authorMarrero, Joséen_US
dc.contributor.authorTorres, Franciscoen_US
dc.contributor.authorGimenez, Diegoen_US
dc.contributor.authorOrtega, José R.en_US
dc.date.accessioned2020-08-03T10:28:42Z-
dc.date.available2020-08-03T10:28:42Z-
dc.date.issued1995en_US
dc.identifier.issn0002-8703en_US
dc.identifier.otherWoS-
dc.identifier.urihttp://hdl.handle.net/10553/73933-
dc.description.abstractTo assess the risk of late side branch occlusion after Palmaz-Schatz stent deployment, we analyzed the angiographic evolution of 62 patients treated by successful stent implantation who had a total of 85 side branches starting from the stented segment. Side branches were considered minor (n = 39) when the diameter was <1 mm and intermediate (n = 46) when the vessel had greater than or equal to 1 mm diameter. One angiographic follow-up study was available in all patients at 8 +/- 5 months. Eight minor branches presented some degree of stenosis at origin before stent deployment (4 totally occluded). After stent deployment, 32 (82%) of 39 remained unchanged and 3 became occluded. Late progression at origin occurred in 4 of 34 (3 occluded). Before stent deployment, 48% of the intermediate branches had some compromise degree at their starting point (1 totally occluded). Eight of 45 intermediate branches became occluded after stent implantation. Late progression at origin happened in 5 of 32 branches (2 occluded). Some degree of follow-up stenosis regression at the origin was observed in 22 (26%) of 85 arteries. Neither clinical nor angiographic factors could be identified as predictors of late side branch occlusion or stenosis progression at its origin. Later occlusion or progression at origin of a side branch covered by a Palmaz-Schatz stent seems to be an uncommon occurrence (7% and 12% respectively) that cannot be predicted by angiographic or clinical factors. On the contrary, regression at follow-up of a side branch-origin stenosis can also come about.en_US
dc.languageengen_US
dc.relation.ispartofThe American heart journalen_US
dc.sourceAmerican Heart Journal [ISSN 0002-8703], v. 129 (3), p. 436-440, (Marzo 1995)en_US
dc.subject320501 Cardiologíaen_US
dc.subject.otherCoronary Angioplastyen_US
dc.subject.otherExperienceen_US
dc.titleFollow-up patency of side branches covered by intracoronary Palmaz-Schatz stenten_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/0002-8703(95)90264-3en_US
dc.identifier.scopus0028941799-
dc.identifier.isiA1995QK46500003-
dc.contributor.authorscopusid7202544866-
dc.contributor.authorscopusid7202723590-
dc.contributor.authorscopusid7006785516-
dc.contributor.authorscopusid7202430759-
dc.contributor.authorscopusid7003549899-
dc.contributor.authorscopusid7005198171-
dc.contributor.authorscopusid7402296666-
dc.contributor.authorscopusid55415591100-
dc.contributor.authorscopusid7005957537-
dc.contributor.authorscopusid57194377147-
dc.contributor.authorscopusid7005459636-
dc.contributor.authorscopusid7402624018-
dc.description.lastpage440en_US
dc.identifier.issue3-
dc.description.firstpage436en_US
dc.relation.volume129en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.contributor.daisngid77557-
dc.contributor.daisngid74576-
dc.contributor.daisngid67522-
dc.contributor.daisngid156230-
dc.contributor.daisngid686157-
dc.contributor.daisngid831427-
dc.contributor.daisngid2740671-
dc.contributor.daisngid1825688-
dc.contributor.daisngid33557-
dc.contributor.daisngid1302579-
dc.contributor.daisngid23347748-
dc.contributor.daisngid2867657-
dc.description.numberofpages5en_US
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:PAN, M-
dc.contributor.wosstandardWOS:MEDINA, A-
dc.contributor.wosstandardWOS:DELEZO, JS-
dc.contributor.wosstandardWOS:ROMERO, M-
dc.contributor.wosstandardWOS:MELIAN, F-
dc.contributor.wosstandardWOS:PAVLOVIC, D-
dc.contributor.wosstandardWOS:HERNANDEZ, E-
dc.contributor.wosstandardWOS:SEGURA, J-
dc.contributor.wosstandardWOS:MARRERO, J-
dc.contributor.wosstandardWOS:TORRES, F-
dc.contributor.wosstandardWOS:GIMENEZ, D-
dc.contributor.wosstandardWOS:ORTEGA, JR-
dc.date.coverdateEnero 1995en_US
dc.identifier.ulpgcen_US
dc.description.scieSCIE
item.grantfulltextopen-
item.fulltextCon texto completo-
Colección:Artículos
miniatura
pdf
Adobe PDF (1,67 MB)
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.