Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/72708
Title: | Corrosion behaviour in physiological fluids of surface films formed on titanium alloys | Authors: | Mirza Rosca, Julia Claudia Vasilescu, E. Drob, P. Vasilescu, C. Drob, S. I. |
UNESCO Clasification: | 330307 Tecnología de la corrosión 3312 Tecnología de materiales 3313 Tecnología e ingeniería mecánicas |
Keywords: | Electrochemical Evaluation In-Vitro Apatite Ti Bioactivity, et al |
Issue Date: | 2012 | Journal: | Materials and Corrosion - Werkstoffe und Korrosion | Abstract: | The properties of the surface films formed on Ti and its Ti5Al4V and Ti6Al3.5Fe alloys by chemical (immersion in 10?M NaOH) and thermal treatment (500 degrees C) were studied in this paper. Their corrosion behaviour in Ringer solution was investigated. After treatments, the sample microhardness was measured. Also, the sample surfaces were observed by an optical microscope before and after immersion in Ringer solutions. The electrochemical behaviour of the surface films obtained by the chemical and thermal treatments was studied using the methods of the electrochemical impedance spectroscopy (EIS) and monitoring of open circuit potentials at different immersion periods (up to 60 days) in Ringer solution. Microhardness increased with the increasing loads for the studied materials, showing the existence of a compact protective layer. Microscopic observations exhibited more compact coatings after 60 days of exposure in Ringer solution, due to the formation of an apatite layer. EIS spectra revealed surface films with two layers: an inner, barrier protective layer and an outer, porous apatite layer. The impedance increases in time denoting that the films have grown by apatite nucleation. Also, EIS spectra showed that the complex treatment by chemical?+?heat method is the most efficiently. For the samples treated by the two processes (chemical?+?heat) the values of the open circuit potentials are nobler than of the chemical treated samples, denoting better protective, bioactive films. | URI: | http://hdl.handle.net/10553/72708 | ISSN: | 0947-5117 | DOI: | 10.1002/maco.201106102 | Source: | Materials and Corrosion-Werkstoffe und Korrosion [ISSN 0947-5117], v. 63 (6), p. 527-533 |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
15
checked on Mar 30, 2025
WEB OF SCIENCETM
Citations
13
checked on Mar 30, 2025
Page view(s)
60
checked on Sep 21, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.