Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/70754
Title: | Automatic detection of anatomical landmarks of the aorta in CTA images | Authors: | Tahoces, Pablo G. Santana-Cedrés, Daniel Alvarez, Luis Alemán-Flores, Miguel Trujillo, Agustín Cuenca, Carmelo Carreira, Jose M. |
UNESCO Clasification: | 220990 Tratamiento digital. Imágenes 120601 Construcción de algoritmos |
Keywords: | Aortic branches Aortic root Computed tomography (Ct) Detection Vessel morphology |
Issue Date: | 2020 | Project: | Nuevos Modelos Matemáticos Para la Segmentación y Clasificación en Imágenes | Journal: | Medical and Biological Engineering and Computing | Abstract: | Computed tomography angiography (CTA) is one of the most common vascular imaging modalities. However, for clinical use, it still requires laborious manual analysis. This study demonstrates the feasibility of a fully automated technology for the accurate detection and identification of several anatomical reference points (landmarks), commonly used in intravascular imaging. This technology uses two different approaches, specially designed for the detection of aortic root and supra-aortic and visceral branches. In order to adjust the parameters of the developed algorithms, a total of 33 computed tomography scans with different types of pathologies were selected. Furthermore, a total of 30 independently selected computed tomography scans were used to assess their performance. Accuracy was evaluated by comparing the locations of reference points manually marked by human experts with those that were automatically detected. For supra-aortic and visceral branches detection, average values of 91.8 % for recall and 98.8 % for precision were obtained. For aortic root detection, the average difference between the positions marked by the experts and those detected by the computer was 5.7 ± 7.3 mm. Finally, diameters and lengths of the aorta were measured at different locations related to the extracted landmarks. Those measurements agreed with the values reported by the literature. | URI: | http://hdl.handle.net/10553/70754 | ISSN: | 0140-0118 | DOI: | 10.1007/s11517-019-02110-x | Source: | Medical & Biological Engineering & Computing [ISSN 0140-0118], n. 68, p. 903–919 |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
12
checked on Nov 10, 2024
WEB OF SCIENCETM
Citations
9
checked on Nov 10, 2024
Page view(s)
208
checked on Aug 10, 2024
Download(s)
51
checked on Aug 10, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.