Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/70137
Título: Preclinical Strength Checking for Artificial Pelvic Prosthesis under Multi-activities - A Case Study
Autores/as: Dong, Enchun
Iqbal, Taimoor
Fu, Jun
Li, Dichen
Liu, Bin
Guo, Zheng
Cuadrado Hernández, Alberto Javier 
Zhen, Zhen
Wang, Ling
Fan, Hongbin
Clasificación UNESCO: 331402 Prótesis
Palabras clave: Bionic Prosthesis
Finite Element Analysis
Multi-Activities
Pelvis
Fecha de publicación: 2019
Publicación seriada: Journal of Bionic Engineering 
Resumen: Customized prostheses are normally employed to reconstruct the biomechanics of the pelvis after resection due to tumors or accidents. The objective of this study is to evaluate the biomechanics of the pelvis under different daily activities and to establish a functional evaluation methodology for the customized prostheses. For this purposes, finite element model of a healthy pelvis as well as a reconstructed pelvic model after type II+III resection were built for biomechanical study. The biomechanical performance of the healthy and reconstructed pelvic model was studied under routine activities including standing, knee bending, sitting down, standing up, walking, stair descent and stair ascent. Subsequently, the strength and stability of the prosthesis were evaluated under these activities. Results showed that, for the heathy pelvic model, the stresses were mainly concentrated around the upper part of the sacrum and the sacroiliac joint undergoing different activities, and the maximum stress occurred during stair ascent. As for the reconstructed pelvis, the stress distribution and the tendency of the maximum stress variation predicted for the bone part during all the activities were similar to those of the natural pelvic model, which indicated that the load transferring function of the reconstructed pelvis could be restored by the prosthesis. Moreover, the predicted maximum von Mises stress of the screws and prosthesis was below the fatigue strength of the 3D printed Ti-6Al-4V, which indicated the prosthesis can provide a reliable mechanical performance after implantation.
URI: http://hdl.handle.net/10553/70137
ISSN: 1672-6529
DOI: 10.1007/s42235-019-0121-5
Fuente: Journal of Bionic Engineering [ISSN 1672-6529], v. 16 (6), p. 1092-1102
Colección:Artículos
Vista completa

Citas SCOPUSTM   

9
actualizado el 14-abr-2024

Citas de WEB OF SCIENCETM
Citations

7
actualizado el 25-feb-2024

Visitas

61
actualizado el 02-mar-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.