Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/58129
Title: | Impact of data averaging strategies on VO2max assessment: mathematical modeling and reliability | Authors: | Martin-Rincon, Marcos González-Henríquez, Juan José Losa Reyna,Jose Perez Suárez,Ismael Ponce González,Jesús Gustavo de La Calle-Herrero, Jaime Perez-Valera, Mario Perez-Lopez, Alberto Curtelin Pérez,David Cherouveim, Evgenia D. Morales-Alamo, David Calbet, José A. |
UNESCO Clasification: | 241106 Fisiología del ejercicio | Keywords: | Sampling Interval Oxygen-Uptake Gas-Exchange Exercise Plateau, et al |
Issue Date: | 2019 | Project: | Desarrollo y Caracterización Molecular de Un Nuevo Modelo de Precondicionamiento Remoto Identificacion E Integracion de Nuevos Factores Moleculares, Fisiologicos y Bioelectricos Determinantes Del Rendimiento en El Ejercicio de Sprint Viabilidad y Sostenibilidad Del Adelgazamiento Mediante Tratamiento Intensificado en Pacientes Con Sobrepeso U Obesidad: Mecanismos Neuroendocrinos y Moleculares |
Journal: | Scandinavian Journal of Medicine and Science in Sports | Abstract: | Background No consensus exists on how to average data to optimize VO2max assessment. Although the VO2max value is reduced with larger averaging blocks, no mathematical procedure is available to account for the effect of the length of the averaging block on VO2max. Aims To determine the effect that the number of breaths or seconds included in the averaging block has on the VO(2max )value and its reproducibility and to develop correction equations to standardize VO2max values obtained with different averaging strategies. Methods Eighty-four subjects performed duplicate incremental tests to exhaustion (IE) in the cycle ergometer and/or treadmill using two metabolic carts (Vyntus and Vmax N29). Rolling breath averages and fixed time averages were calculated from breath-by-breath data from 6 to 60 breaths or seconds. Results VO2max decayed from 6 to 60 breath averages by 10% in low fit (VO2max < 40 mL kg(-1) min(-1)) and 6.7% in trained subjects. The VO2max averaged from a similar number of breaths or seconds was highly concordant (CCC > 0.97). There was a linear-log relationship between the number of breaths or seconds in the averaging block and VO2max (R-2 > 0.99, P < 0.001), and specific equations were developed to standardize VO2max values to a fixed number of breaths or seconds. Reproducibility was higher in trained than low-fit subjects and not influenced by the averaging strategy, exercise mode, maximal respiratory rate, or IE protocol. Conclusions The VO(2max )decreases following a linear-log function with the number of breaths or seconds included in the averaging block and can be corrected with specific equations as those developed here. | URI: | http://hdl.handle.net/10553/58129 | ISSN: | 0905-7188 | DOI: | 10.1111/sms.13495 | Source: | Scandinavian Journal of Medicine and Science in Sports [ISSN 0905-7188], v. 29 (10), p. 1473-1488 |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
34
checked on Nov 17, 2024
WEB OF SCIENCETM
Citations
34
checked on Nov 17, 2024
Page view(s)
129
checked on Feb 17, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.