Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/55418
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | León-Zerpa, Federico | en_US |
dc.contributor.author | Ramos, Alejandro | en_US |
dc.date.accessioned | 2019-05-17T14:27:26Z | - |
dc.date.available | 2019-05-17T14:27:26Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.issn | 1934-8975 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/55418 | - |
dc.description.abstract | Regarding the studies of other authors about energy performance of a reverse osmosis desalination plant operating with variable pressure; about desalination efficiency in their different recent articles, we continued working in this way researching in a real seawater reverse osmosis plant following the items below. The objectives of this test are to get the minimum electrical consumption and energy costs for the operation of a sea water desalination plant using membranes. We need to compare the performance of the different membranes manufacturer’s and to determine, under this new thermal scenario, the optimal configuration to get the water quality and quantity needs with the minimum energy consumption. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Energy and Power Engineering | en_US |
dc.source | Journal of Energy and Power Engineering [ISSN 1934-8975], v. 10, p. 628-633 | en_US |
dc.subject | 3308 Ingeniería y tecnología del medio ambiente | en_US |
dc.subject.other | Minimum energy consumption | en_US |
dc.subject.other | Energetic efficiency | en_US |
dc.subject.other | High efficiency membrane | en_US |
dc.subject.other | Energy costs | en_US |
dc.title | Study of high efficiency membrane pilot test for membrane design optimisation in order to reduce the electrical consumption | en_US |
dc.type | info:eu-repo/semantics/article | es |
dc.type | Article | es |
dc.identifier.doi | 10.17265/1934-8975/2016.10.007 | en_US |
dc.identifier.eissn | 1934-8983 | - |
dc.description.lastpage | 633 | - |
dc.description.firstpage | 628 | - |
dc.relation.volume | 10 | - |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.ulpgc | Sí | es |
item.fulltext | Con texto completo | - |
item.grantfulltext | open | - |
crisitem.author.dept | GIR IUNAT: Control analítico de fuentes medioambientales | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.dept | GIR IUNAT: Control analítico de fuentes medioambientales | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.orcid | 0000-0003-2284-8400 | - |
crisitem.author.orcid | 0000-0001-5759-4469 | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.fullName | León Zerpa, Federico Antonio | - |
crisitem.author.fullName | Ramos Martín, Alejandro | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.