Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/53948
Title: Transport characterization in flat reverse osmosis membranes: Utilization of the Kimura-Sourirajan analysis method for the determination of mass transfer coefficient K, transport parameter D-am/K delta and permeability constant A
Authors: Gotor, AG
Bachir, SI
Baez, OP
Issue Date: 1999
Publisher: 0011-9164
Journal: Desalination (Amsterdam) 
Conference: European Conference on Desalination and the Environment 
Abstract: A study was carried out on a NaCl H2O RO thin film composite reverse osmosis membrane system to characterize these membranes, determine their performance and predict the effects of pressure and solute concentration in the feed using the correlation from the Kimura Sourirajan analysis. The effect of the solute concentration in the feed (0.0043-0.086 molal) operating at pressures of 500-2000 kPa was studied. The permeability constant, A, and the transport parameter D-Am/k delta for CA 990 PP and HR 98 PP flat membranes were calculated and the results from both membranes were compared. The M20 lab unit had a total permeation surface of 0.72 m(2) when all 20 membrane pairs were installed. During the experiments one pair of membranes was installed, resulting in a permeation surface of 0.036 m(2).
URI: http://hdl.handle.net/10553/53948
ISSN: 0011-9164
Source: Desalination[ISSN 0011-9164],v. 126 (1-3), p. 115-118
Appears in Collections:Artículos
Show full item record

WEB OF SCIENCETM
Citations

2
checked on Feb 25, 2024

Page view(s)

48
checked on Mar 9, 2024

Google ScholarTM

Check


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.