Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/52560
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Borrego, Leopoldo | en_US |
dc.contributor.author | Hernández, Noelia | en_US |
dc.contributor.author | Hernández, Zaida | en_US |
dc.contributor.author | Peñate, Yeray | en_US |
dc.date.accessioned | 2018-11-30T11:29:36Z | - |
dc.date.available | 2018-11-30T11:29:36Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.issn | 0011-9059 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/52560 | - |
dc.description.abstract | Background: Povidone-iodine solution is an antiseptic that is used worldwide as surgical paint and is considered to have a low irritant potential. Post-surgical severe irritant dermatitis has been described after the misuse of this antiseptic in the surgical setting. Methods: Between January 2011 and June 2013, 27 consecutive patients with post-surgical contact dermatitis localized outside of the surgical incision area were evaluated. Thirteen patients were also available for patch testing. Results: All patients developed dermatitis the day after the surgical procedure. Povidone-iodine solution was the only liquid in contact with the skin of our patients. Most typical lesions were distributed in a double lumbar parallel pattern, but they were also found in a random pattern or in areas where a protective pad or an occlusive medical device was glued to the skin. The patch test results with povidone-iodine were negative. Conclusions: Povidone-iodine-induced post-surgical dermatitis may be a severe complication after prolonged surgical procedures. As stated in the literature and based on the observation that povidone-iodine-induced contact irritant dermatitis occurred in areas of pooling or occlusion, we speculate that povidone-iodine together with occlusion were the causes of the dermatitis epidemic that occurred in our surgical setting. Povidone-iodine dermatitis is a problem that is easily preventable through the implementation of minimal routine changes to adequately dry the solution in contact with the skin. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | International journal of dermatology | en_US |
dc.source | International Journal of Dermatology [ISSN 0011-9059], v. 55, p. 540-545 | en_US |
dc.subject | 320106 Dermatología | en_US |
dc.subject.other | Chemical Burn | en_US |
dc.subject.other | Tourniquet | en_US |
dc.subject.other | Surgery | en_US |
dc.title | Povidone-iodine induced post-surgical irritant contact dermatitis localized outside of the surgical incision area. Report of 27 cases and a literature review | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1111/ijd.12957 | en_US |
dc.identifier.scopus | 84952837427 | - |
dc.identifier.isi | 000374003900028 | - |
dc.contributor.authorscopusid | 7004025265 | - |
dc.contributor.authorscopusid | 35221648800 | - |
dc.contributor.authorscopusid | 6602279417 | - |
dc.contributor.authorscopusid | 15124154700 | - |
dc.description.lastpage | 545 | en_US |
dc.identifier.issue | 5 | - |
dc.description.firstpage | 540 | en_US |
dc.relation.volume | 55 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 6293174 | - |
dc.contributor.daisngid | 1180274 | - |
dc.contributor.daisngid | 5646047 | - |
dc.contributor.daisngid | 2129803 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Borrego, L | - |
dc.contributor.wosstandard | WOS:Hernandez, N | - |
dc.contributor.wosstandard | WOS:Hernandez, Z | - |
dc.contributor.wosstandard | WOS:Penate, Y | - |
dc.date.coverdate | Mayo 2016 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.sjr | 0,478 | |
dc.description.jcr | 1,56 | |
dc.description.sjrq | Q3 | |
dc.description.jcrq | Q3 | |
dc.description.scie | SCIE | |
item.fulltext | Con texto completo | - |
item.grantfulltext | open | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0002-0199-2756 | - |
crisitem.author.fullName | Borrego Hernando, Leopoldo | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
23
checked on Sep 29, 2024
WEB OF SCIENCETM
Citations
20
checked on Sep 29, 2024
Page view(s)
60
checked on Dec 9, 2023
Download(s)
518
checked on Dec 9, 2023
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.