Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/52456
Campo DC Valoridioma
dc.contributor.authorRavelo-García, A. G.
dc.contributor.authorNavarro-Mesa, J. L.
dc.contributor.authorMurillo-Díaz, M. J.
dc.contributor.authorJuliá-Serdá, J. G.
dc.date.accessioned2018-11-25T20:29:55Z-
dc.date.available2018-11-25T20:29:55Z-
dc.date.issued2004
dc.identifier.issn0276-6574
dc.identifier.urihttp://hdl.handle.net/10553/52456-
dc.description.abstractIn this paper we present a method for the automatic detection of sleep apnoea/Hypopnoea syndrome. This method comprises five steps. These are, signals segmentation, RR series generation, feature extraction, model training and classification. We explore the usage of the RR series and oxygen saturation (oximetry) signals both independently and jointly. Our results show that the joint usage of both improves the results obtained from the use of RR series or oximetry alone. A variety of parameterization techniques are studied in order to extract the relevant features from the signals. For the classification task we propose a two-stage strategy in which epochs are first classified by means of the power ratios. If this classification is not found reliable a Gaussian-mixture-model-based classification is applied in a second stage. A global classification of each subject is given attending to the amount of apnoea epochs. For the experiments we have used 66 subjects. The best results of our method show a 100% success in the global apnoea classification task.
dc.publisher0276-6574
dc.relation.ispartofComputers in Cardiology
dc.sourceComputers in Cardiology[ISSN 0276-6574],v. 31, p. 305-308
dc.subject.otherHeart-Rate-Variability
dc.subject.otherApnea
dc.subject.otherElectrocardiogram
dc.titleApplication of RR series and oximetry to a statistical classifier for the detection of sleep apnoea/Hypopnoea
dc.typeinfo:eu-repo/semantics/conferenceObjectes
dc.typeConferenceObjectes
dc.relation.conference31st Annual Scientific Meeting on Computers in Cardiology
dc.relation.conferenceComputers in Cardiology 2004
dc.identifier.scopus28244435749
dc.identifier.isi000229753800077
dc.contributor.authorscopusid9634135600
dc.contributor.authorscopusid9634488300
dc.contributor.authorscopusid9633795700
dc.contributor.authorscopusid9633428900
dc.description.lastpage308
dc.description.firstpage305
dc.relation.volume31
dc.type2Actas de congresoses
dc.contributor.daisngid1986395
dc.contributor.daisngid2630721
dc.contributor.daisngid32696404
dc.contributor.daisngid34016447
dc.contributor.wosstandardWOS:Ravelo-Garcia, A
dc.contributor.wosstandardWOS:Navarro-Mesa, J
dc.contributor.wosstandardWOS:Murillo-Diaz, M
dc.contributor.wosstandardWOS:Julia-Serda, JG
dc.date.coverdateDiciembre 2004
dc.identifier.conferenceidevents120454
dc.identifier.ulpgces
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.event.eventsstartdate19-09-2004-
crisitem.event.eventsstartdate19-09-2004-
crisitem.event.eventsenddate22-09-2004-
crisitem.event.eventsenddate22-09-2004-
crisitem.author.deptGIR IDeTIC: División de Procesado Digital de Señales-
crisitem.author.deptIU para el Desarrollo Tecnológico y la Innovación-
crisitem.author.deptDepartamento de Señales y Comunicaciones-
crisitem.author.deptGIR IDeTIC: División de Procesado Digital de Señales-
crisitem.author.deptIU para el Desarrollo Tecnológico y la Innovación-
crisitem.author.deptDepartamento de Señales y Comunicaciones-
crisitem.author.deptDepartamento de Señales y Comunicaciones-
crisitem.author.orcid0000-0002-8512-965X-
crisitem.author.orcid0000-0003-3860-3424-
crisitem.author.parentorgIU para el Desarrollo Tecnológico y la Innovación-
crisitem.author.parentorgIU para el Desarrollo Tecnológico y la Innovación-
crisitem.author.fullNameRavelo García, Antonio Gabriel-
crisitem.author.fullNameNavarro Mesa, Juan Luis-
Colección:Actas de congresos
Vista resumida

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.