Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/52288
Campo DC Valoridioma
dc.contributor.authorGonzalez-Reimers, E.en_US
dc.contributor.authorVelasco Vázquez, Francisco Javieren_US
dc.contributor.authorArnay-de-la-Rosa, M.en_US
dc.contributor.authorMachado-Calvo, M.en_US
dc.date.accessioned2018-11-25T19:02:28Z-
dc.date.available2018-11-25T19:02:28Z-
dc.date.issued2007en_US
dc.identifier.issn0305-4403en_US
dc.identifier.urihttp://hdl.handle.net/10553/52288-
dc.description.abstractIn this study, we examine the value of bone density assessed by computed tomography (QCT) of the right tibia in the diagnosis of low bonemass in prehistoric bones. Trabecular bone mass (TBM) was assessed by histomorphometry in undecalcified bone sections of a small part of theproximal epiphysis of the right tibia of 78 prehispanic individuals. Bone density was also assessed in the proximal epiphysis of the right tibia, inan area of cancellous bone immediately adjacent to the wedge which was destined to histomorphometry, with the aid of a Tomoscan 60 TXÔ(Philipps Medical System, Eindhoven, The Netherlands) using a phantom of hydroxyapatite included in plastic resin at three known concentra-tions (50, 100 and 200 mg/cc) and ethanol as fat equivalent. Bone density (as bone hydroxyapatite concentration in milligram per cubic centi-meter) was calculated by means of a specific software tool (QCT Bone Mineral Analysis System, Image Analysis, California). We comparedbone density assessed with QCT with TBM in these individuals, and also, with the results obtained from a modern control group. We calculatedthe median TBM of the prehispanic sample and tested the sensitivity, specificity, and overall accuracy of QCT in diagnosing TBM values belowthe median. We later performed the same analyses on 24 more prehispanic individuals. Both QCT (t¼5.61,p<0.001) and TBM (t¼3.79,p<0.001) were significantly lower among the prehispanic individuals than among the control ones. QCT showed a significant relationshipwith TBM (r¼0.41,p<0.001). QCT values below 100 mg/cc serve to establish a diagnosis of low TBM values with a sensitivity of 82.1%and a specificity of 41%. In the test group sensitivity was 83.3% and specificity, 50%.In conclusion, in contrast with the results obtained in clinical studies, QCT serves only to obtain a rough estimate of TBM in prehistoricsamples. The relatively low accuracy may be due to the lack of soft tissue and the air bubbles entrapped within the cancellous bone, which persisteven after prolonged submersion of the bones in a water bath.Ó2006 Elsevier Ltd. All rights reserved.en_US
dc.languageengen_US
dc.publisher0305-4403
dc.relation.ispartofJournal of Archaeological Scienceen_US
dc.sourceJournal of Archaeological Science[ISSN 0305-4403],v. 34, p. 554-561en_US
dc.subject550501 Arqueologíaen_US
dc.subject32 Ciencias médicasen_US
dc.subject.otherOsteopeniaen_US
dc.subject.otherComputed tomographyen_US
dc.subject.otherBone densityen_US
dc.subject.otherBone-histomorphometryen_US
dc.subject.otherPrehistoric Canary Islandsen_US
dc.subject.otherOsteoporosisen_US
dc.titleQuantitative computerized tomography for the diagnosis of osteopenia in prehistoric skeletal remainsen_US
dc.typeinfo:eu-repo/semantics/articlees
dc.typeArticlees
dc.identifier.doi10.1016/j.jas.2006.06.004en_US
dc.identifier.scopus33845514762-
dc.contributor.authorscopusid7004694989-
dc.contributor.authorscopusid8108100300-
dc.contributor.authorscopusid6602716669-
dc.contributor.authorscopusid8108101300-
dc.description.lastpage561-
dc.description.firstpage554-
dc.relation.volume34-
dc.investigacionArtes y Humanidadesen_US
dc.type2Artículoen_US
dc.identifier.ulpgces
dc.description.jcr1,439
dc.description.jcrqQ1
dc.description.ahciAHCI
dc.description.scieSCIE
dc.description.ssciSSCI
dc.description.erihplusERIH PLUS
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR Investigación en Arqueología y Patrimonio-
crisitem.author.orcid0000-0003-0339-3500-
crisitem.author.parentorgDepartamento de Ciencias Históricas-
crisitem.author.fullNameVelazco Vázquez,Francisco Javier-
Colección:Artículos
Vista resumida

Citas SCOPUSTM   

16
actualizado el 17-nov-2024

Citas de WEB OF SCIENCETM
Citations

11
actualizado el 17-nov-2024

Visitas

73
actualizado el 17-feb-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.