Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/50531
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Bueno, C. | |
dc.contributor.author | Carta, J. A. | |
dc.date.accessioned | 2018-11-24T16:46:05Z | - |
dc.date.available | 2018-11-24T16:46:05Z | - |
dc.date.issued | 2005 | |
dc.identifier.issn | 0038-092X | |
dc.identifier.uri | http://hdl.handle.net/10553/50531 | - |
dc.description.abstract | In this paper a model is presented for the technical and economic sizing of the various components that make up medium sized wind-powered pumped hydrostorage systems. A further aim of this model is the optimisation of the operation of such systems, thereby making full use of the synergy of the unit as a whole.A general model is described for use as an analytical tool in implementing such systems in topographically suitable sites with sufficient wind resources. The general model developed allows for six strategies for the system operating configuration. Each strategy is based on the hypothesis that there is a centralised operator to control all the system components, except for the load systems.The characteristics and unit energy cost of each technically feasible combination of components are determined by applying the model. This enables the selection of the most viable composition for the system from an economic point of view given certain technical restrictions. (c) 2004 Elsevier Ltd. All rights reserved. | |
dc.publisher | 0038-092X | |
dc.relation.ispartof | Solar Energy | |
dc.source | Solar Energy[ISSN 0038-092X],v. 78, p. 382-395 | |
dc.subject.other | Canary-Islands | |
dc.title | Technical-economic analysis of wind-powered pumped hydrostorage systems. Part I: Model development | |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1016/j.solener.2004.08.006 | |
dc.identifier.scopus | 13844253393 | |
dc.identifier.isi | 000227686800004 | |
dc.contributor.authorscopusid | 7005223381 | |
dc.contributor.authorscopusid | 7003652043 | |
dc.description.lastpage | 395 | |
dc.description.firstpage | 382 | |
dc.relation.volume | 78 | |
dc.type2 | Artículo | es |
dc.contributor.daisngid | 27849251 | |
dc.contributor.daisngid | 1198474 | |
dc.contributor.wosstandard | WOS:Bueno, C | |
dc.contributor.wosstandard | WOS:Carta, JA | |
dc.date.coverdate | Marzo 2005 | |
dc.identifier.ulpgc | Sí | es |
dc.description.jcr | 0,868 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.orcid | 0000-0003-1379-0075 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Carta González, José Antonio | - |
Colección: | Artículos |
Citas SCOPUSTM
85
actualizado el 30-mar-2025
Citas de WEB OF SCIENCETM
Citations
60
actualizado el 30-mar-2025
Visitas
106
actualizado el 18-ene-2025
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.