Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/49716
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Rodriguez-Florido, M. A. | en_US |
dc.contributor.author | Westin, C. F. | en_US |
dc.contributor.author | Ruiz-Alzola, J. | en_US |
dc.date.accessioned | 2018-11-24T10:07:34Z | - |
dc.date.available | 2018-11-24T10:07:34Z | - |
dc.date.issued | 2004 | en_US |
dc.identifier.isbn | 0780383885 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/49716 | - |
dc.description.abstract | In this paper, we present a new non-iterative anisotropic method to regularize vector and higher order tensor fields. The driving application for this work is filtering data from diffusion tensor imaging. Our scheme is based on a multidimensional anisotropic adaptive filtering. The method is based on first estimating the local structure of the field and, then, combining the outputs of a set of steerable filter basis responses to the tensor field, which are adaptively weighted depending on the local structure. Promising results are presented from experiments on both synthetic data and real diffusion tensor MRI. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano | en_US |
dc.source | 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano,v. 1, p. 336-339 | en_US |
dc.subject | 3307 Tecnología electrónica | en_US |
dc.subject.other | Tensor fields | en_US |
dc.subject.other | Tensor imaging | en_US |
dc.subject.other | Anisotropic method | en_US |
dc.subject.other | Adaptive filters | en_US |
dc.title | DT-MRI regularization using anisotropic tensor field filtering | en_US |
dc.type | info:eu-repo/semantics/conferenceObject | en_US |
dc.type | ConferenceObject | en_US |
dc.relation.conference | 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano | en_US |
dc.identifier.scopus | 17144416522 | - |
dc.identifier.isi | 000227671300085 | - |
dc.contributor.authorscopusid | 6507509943 | - |
dc.contributor.authorscopusid | 35477140400 | - |
dc.contributor.authorscopusid | 56614041800 | - |
dc.contributor.authorscopusid | 6603762323 | - |
dc.description.lastpage | 339 | en_US |
dc.description.firstpage | 336 | en_US |
dc.relation.volume | 1 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Actas de congresos | en_US |
dc.contributor.daisngid | 2496101 | - |
dc.contributor.daisngid | 17916575 | - |
dc.contributor.daisngid | 920778 | - |
dc.description.numberofpages | 4 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Rodriguez-Florido, MA | - |
dc.contributor.wosstandard | WOS:Westin, CE | - |
dc.contributor.wosstandard | WOS:Ruiz-Alzola, J | - |
dc.date.coverdate | Diciembre 2004 | en_US |
dc.identifier.conferenceid | events120445 | - |
dc.identifier.ulpgc | Sí | es |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.orcid | 0000-0002-3545-2328 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Ruiz Alzola, Juan Bautista | - |
crisitem.event.eventsstartdate | 15-04-2004 | - |
crisitem.event.eventsenddate | 18-04-2004 | - |
Colección: | Actas de congresos |
Citas SCOPUSTM
6
actualizado el 30-mar-2025
Citas de WEB OF SCIENCETM
Citations
2
actualizado el 25-feb-2024
Visitas
91
actualizado el 01-feb-2025
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.