Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/49716
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rodriguez-Florido, M. A. | en_US |
dc.contributor.author | Westin, C. F. | en_US |
dc.contributor.author | Ruiz-Alzola, J. | en_US |
dc.date.accessioned | 2018-11-24T10:07:34Z | - |
dc.date.available | 2018-11-24T10:07:34Z | - |
dc.date.issued | 2004 | en_US |
dc.identifier.isbn | 0780383885 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/49716 | - |
dc.description.abstract | In this paper, we present a new non-iterative anisotropic method to regularize vector and higher order tensor fields. The driving application for this work is filtering data from diffusion tensor imaging. Our scheme is based on a multidimensional anisotropic adaptive filtering. The method is based on first estimating the local structure of the field and, then, combining the outputs of a set of steerable filter basis responses to the tensor field, which are adaptively weighted depending on the local structure. Promising results are presented from experiments on both synthetic data and real diffusion tensor MRI. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano | en_US |
dc.source | 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano,v. 1, p. 336-339 | en_US |
dc.subject | 3307 Tecnología electrónica | en_US |
dc.subject.other | Tensor fields | en_US |
dc.subject.other | Tensor imaging | en_US |
dc.subject.other | Anisotropic method | en_US |
dc.subject.other | Adaptive filters | en_US |
dc.title | DT-MRI regularization using anisotropic tensor field filtering | en_US |
dc.type | info:eu-repo/semantics/conferenceObject | en_US |
dc.type | ConferenceObject | en_US |
dc.relation.conference | 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano | en_US |
dc.identifier.scopus | 17144416522 | - |
dc.identifier.isi | 000227671300085 | - |
dc.contributor.authorscopusid | 6507509943 | - |
dc.contributor.authorscopusid | 35477140400 | - |
dc.contributor.authorscopusid | 56614041800 | - |
dc.contributor.authorscopusid | 6603762323 | - |
dc.description.lastpage | 339 | en_US |
dc.description.firstpage | 336 | en_US |
dc.relation.volume | 1 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Actas de congresos | en_US |
dc.contributor.daisngid | 2496101 | - |
dc.contributor.daisngid | 17916575 | - |
dc.contributor.daisngid | 920778 | - |
dc.description.numberofpages | 4 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Rodriguez-Florido, MA | - |
dc.contributor.wosstandard | WOS:Westin, CE | - |
dc.contributor.wosstandard | WOS:Ruiz-Alzola, J | - |
dc.date.coverdate | Diciembre 2004 | en_US |
dc.identifier.conferenceid | events120445 | - |
dc.identifier.ulpgc | Sí | es |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.event.eventsstartdate | 15-04-2004 | - |
crisitem.event.eventsenddate | 18-04-2004 | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.orcid | 0000-0002-3545-2328 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Ruiz Alzola, Juan Bautista | - |
Appears in Collections: | Actas de congresos |
SCOPUSTM
Citations
6
checked on Nov 17, 2024
WEB OF SCIENCETM
Citations
2
checked on Feb 25, 2024
Page view(s)
39
checked on May 11, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.