Resumen: Objective To evaluate whether follow-up of patients with obstructive sleep apnoea (OSA) undergoing CPAP treatment could be performed in primary care (PC) settings.Design Non-inferiority, randomised, prospective controlled study.Settings Sleep unit (SU) at the University Hospital and in 8 PC units in Lleida, Spain.Participants Patients with OSA were randomised to be followed up at the SU or PC units over a 6-month period.Main outcomes measured The primary outcome was CPAP compliance at 6 months. The secondary outcomes were Epworth Sleep Scale (ESS) score, EuroQoL, patient satisfaction, body mass index (BMI), blood pressure and cost-effectiveness.Results We included 101 patients in PC ((mean +/- SD) apnoea-hypopnoea index (AHI) 50.8 +/- 22.9/h, age 56.2 +/- 11 years, 74% male) and 109 in the SU (AHI 51.4 +/- 24.4/h, age 55.8 +/- 11 years, 77% male)). The CPAP compliance was (mean (95% CI) 4.94 (4.47 to 5.5) vs 5.23 (4.79 to 5.66) h, p=0.18) in PC and SU groups, respectively. In the SU group, there were greater improvements in ESS scores (mean change 1.79, 95% CI +0.05 to +3.53, p=0.04) and patient satisfaction (-1.49, 95% CI -2.22 to -0.76); there was a significant mean difference in BMI between the groups (0.57, 95% CI +0.01 to +1.13, p=0.04). In the PC setting, there was a cost saving of 60%, with similar effectiveness, as well as a decrease in systolic blood pressure (-5.32; 95% CI -10.91 to +0.28, p=0.06).Conclusions For patients with OSA, treatment provided in a PC setting did not result in worse CPAP compliance compared with a specialist model and was shown to be a cost-effective alternative.
URI: http://hdl.handle.net/10553/48758
ISSN: 0040-6376
DOI: 10.1136/thoraxjnl-2014-206287
Fuente: Thorax[ISSN 0040-6376],v. 70, p. 346-352
Colección:Artículos
Vista completa

Citas SCOPUSTM   

52
actualizado el 24-mar-2024

Citas de WEB OF SCIENCETM
Citations

48
actualizado el 25-feb-2024

Visitas

22
actualizado el 12-ago-2023

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.