Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/48756
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Castaneda, F. | en_US |
dc.contributor.author | Hunter, D. W. | en_US |
dc.contributor.author | Maynar-Moliner, M. | en_US |
dc.contributor.author | Letourneau, J. G. | en_US |
dc.contributor.author | Amplatz, K. | en_US |
dc.date.accessioned | 2018-11-24T00:39:13Z | - |
dc.date.available | 2018-11-24T00:39:13Z | - |
dc.date.issued | 1988 | en_US |
dc.identifier.issn | 0739-9529 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/48756 | - |
dc.description.abstract | As balloon catheters have been refined, they have been used with increasing frequency for percutaneous procedures in almost all systems, including the biliary. We report a case in which bile duct dilation was only partially successful using the new combined percutaneous and endoscopic retrograde cholangiopancreatography (ERCP) technique due to the rigid fibrotic nature of the obstruction. During a subsequent dilation through the percutaneous tract, the common hepatic duct was ruptured, which resulted in severe bleeding into the ducts in addition to extravasation of contrast into the extraductal tissues. Conservative measures precluded the need for surgical intervention. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Seminars in Interventional Radiology | en_US |
dc.source | Seminars in Interventional Radiology[ISSN 0739-9529],v. 5(4), p. 289-292 | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 320111 Radiología | en_US |
dc.subject.other | Hepatic duct rupture | en_US |
dc.subject.other | Ballon dilation | en_US |
dc.title | Common hepatic duct rupture due to excessive balloon dilation. Case report | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1055/s-2008-1075975 | en_US |
dc.identifier.scopus | 0024266608 | - |
dc.contributor.authorscopusid | 7006302979 | - |
dc.contributor.authorscopusid | 7402537356 | - |
dc.contributor.authorscopusid | 6602289978 | - |
dc.contributor.authorscopusid | 7006450309 | - |
dc.contributor.authorscopusid | 7101849328 | - |
dc.description.lastpage | 292 | en_US |
dc.description.firstpage | 289 | en_US |
dc.relation.volume | 5 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 4 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Diciembre 1988 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.scie | SCIE | - |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUIBS: Tecnología Médica y Audiovisual | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.orcid | 0000-0001-9154-0712 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Maynar Moliner,Manuel | - |
Appears in Collections: | Artículos |
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.