Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/48342
Campo DC Valoridioma
dc.contributor.authorPonce-González, J. G.en_US
dc.contributor.authorSanchis-Moysi, J.en_US
dc.contributor.authorGonzalez-Henriquez, J. J.en_US
dc.contributor.authorArteaga Ortiz, Rafael Ángelen_US
dc.contributor.authorCalbet, J. A.L.en_US
dc.contributor.authorDorado, C.en_US
dc.contributor.otherCecilia, Dorado-Garcia-
dc.contributor.otherGonzalez-Henriquez, Juan Jose-
dc.contributor.otherPonce Gonzalez, Jesus Gustavo-
dc.contributor.otherCalbet, Jose A-
dc.contributor.otherSANCHIS-MOYSI, JOAQUIN-
dc.date.accessioned2018-11-23T20:53:35Z-
dc.date.available2018-11-23T20:53:35Z-
dc.date.issued2014en_US
dc.identifier.issn0022-4707en_US
dc.identifier.urihttp://hdl.handle.net/10553/48342-
dc.description.abstractBackground. The aim was to develop a unipedal stance test for the assessment of balance using a force platform.Methods. A single-leg balance test was conducted in 23 students (mean +/- SD) age: 23 +/- 3 years) in a standard position limiting the movement of the arms and non-supporting leg. Six attempts, with both the jumping (JL) and the contralateral leg (CL), were performed under 3 conditions: 1) eyes opened; 2) eyes closed; 3) eyes opened and executing a precision task. The same protocol was repeated two-week apart.Results. The mean and the best result of the six attempts performed each day were taken as representative of balance. The speed of the centre of pressure (CP-Speed) showed excellent reliability for the "best result" analysis in all tests (ICCs 0.87-0.97), except in the test with the eyes closed performed on the CL (ICC<0.4). The CP-Speed had better reliability with the "best result" than with the "mean result" analysis (P<0.05), whilst no significant differences were observed between the JL and the CL (P=0.71 and P=0.96 for mean and best results analysis, respectively). A lower dispersion in the Bland and Altman graph was observed with the eyes opened than closed, and the dynamic test.Conclusion. The single-leg stance balance test proposed is a reliable method to assess balance, especially when performed in a static position, with the eyes opened and using the best result of six attempts as reference, independently of the stance leg.
dc.languageengen_US
dc.publisher0022-4707-
dc.relation.ispartofJournal of Sports Medicine and Physical Fitnessen_US
dc.sourceJournal of Sports Medicine and Physical Fitness[ISSN 0022-4707],v. 54, p. 108-117en_US
dc.subject241106 Fisiología del ejercicioen_US
dc.subject.otherPostural balanceen_US
dc.subject.otherMuscle strengthen_US
dc.subject.otherAgeden_US
dc.titleA reliable unipedal stance test for the assessment of balance using a force platformen_US
dc.typeinfo:eu-repo/semantics/Articlees
dc.typeArticlees
dc.identifier.scopus84895826421-
dc.identifier.scopusWOS:000332051900015-
dc.identifier.isi000332051900015-
dcterms.isPartOfJournal Of Sports Medicine And Physical Fitness-
dcterms.sourceJournal Of Sports Medicine And Physical Fitness[ISSN 0022-4707],v. 54 (1), p. 108-117-
dc.contributor.authorscopusid25628359100-
dc.contributor.authorscopusid6507016623-
dc.contributor.authorscopusid56061170000-
dc.contributor.authorscopusid36909495100-
dc.contributor.authorscopusid7004323423-
dc.contributor.authorscopusid6602610320
dc.contributor.authorscopusid56151351600-
dc.description.lastpage117-
dc.description.firstpage108-
dc.relation.volume54-
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.identifier.wosWOS:000332051900015-
dc.contributor.daisngid7526316
dc.contributor.daisngid1264657-
dc.contributor.daisngid1763347-
dc.contributor.daisngid2563867-
dc.contributor.daisngid8506709-
dc.contributor.daisngid90295-
dc.contributor.daisngid629383-
dc.identifier.investigatorRIDB-4586-2010-
dc.identifier.investigatorRIDK-8808-2014-
dc.identifier.investigatorRIDH-9500-2015-
dc.identifier.investigatorRIDH-6693-2015-
dc.identifier.investigatorRIDH-7017-2015-
dc.contributor.wosstandardWOS:Ponce-Gonzalez, JG
dc.contributor.wosstandardWOS:Sanchis-Moysi, J
dc.contributor.wosstandardWOS:Gonzalez-Henriquez, JJ
dc.contributor.wosstandardWOS:Arteaga-Ortiz, R
dc.contributor.wosstandardWOS:Calbet, JAL
dc.contributor.wosstandardWOS:Dorado, C
dc.date.coverdateFebrero 2014
dc.identifier.ulpgces
dc.description.sjr0,517
dc.description.jcr0,972
dc.description.sjrqQ2
dc.description.jcrqQ3
dc.description.scieSCIE
item.fulltextSin texto completo-
item.grantfulltextnone-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Educación Física-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Matemáticas-
crisitem.author.deptGIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptDepartamento de Física-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Educación Física-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Educación Física-
crisitem.author.orcid0000-0001-6602-7087-
crisitem.author.orcid0000-0002-0622-5580-
crisitem.author.orcid0000-0002-3651-1908-
crisitem.author.orcid0000-0002-9215-6234-
crisitem.author.orcid0000-0001-6616-6810-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameSanchís Moysi, Joaquín-
crisitem.author.fullNameGonzález Henríquez, Juan José-
crisitem.author.fullNameArteaga Ortiz, Rafael Ángel-
crisitem.author.fullNameLópez Calbet, José Antonio-
crisitem.author.fullNameDorado García, Cecilia-
Colección:Artículos
Vista resumida

Citas SCOPUSTM   

14
actualizado el 05-may-2024

Citas de WEB OF SCIENCETM
Citations

8
actualizado el 20-feb-2022

Visitas

95
actualizado el 30-sep-2023

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.