Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/48056
Campo DC Valoridioma
dc.contributor.authorDe Rivera, M. Rodríguezen_US
dc.contributor.authorSocorro, F.en_US
dc.date.accessioned2018-11-23T18:36:35Z-
dc.date.available2018-11-23T18:36:35Z-
dc.date.issued2005en_US
dc.identifier.issn1388-6150en_US
dc.identifier.urihttp://hdl.handle.net/10553/48056-
dc.description.abstractIsothermal titration microcalorimeters are submerged in an ambience at constant temperature and, this is the reason why there should not be variations in the baseline; but the experimental measures show that, in some cases, it is produced a jump in the baseline after the liquid injection. In this paper, it is studied the origin of this variation of the baseline in order to avoid it, if it is possible, or correct it and thus, to determine with the minimum error the amounts of energy or power developed in the energetic process that is being studied. The experimental results that are shown support the hypothesis that states that the cause of the baseline jump in an isothermal microcalorimeter is the variation of the thermal coupling between the content of the mixture cell and the axis of the stirrer, which is coupled, at the same time, with an area with a temperature slightly lower (in this case) than the thermostat temperature. This jump is independent from the dissipation and it always has the same sign. The magnitude of the baseline jump is variable and it mainly depends on the volume that the liquid content in a cell reaches and the placement of the stirrer within the cell, that can be changed in the handling process.en_US
dc.languageengen_US
dc.publisher1388-6150
dc.relation.ispartofJournal of Thermal Analysis and Calorimetryen_US
dc.sourceJournal of Thermal Analysis and Calorimetry [ISSN 1388-6150], v. 80, p. 769-773en_US
dc.subject2213 Termodinámicaen_US
dc.subject220408 Líquidosen_US
dc.subject.otherBaselineen_US
dc.subject.otherBaseline correctionen_US
dc.subject.otherIsothermal titration microcalorimeteren_US
dc.subject.otherLiquid injection calorimeteren_US
dc.titleBaseline changes in an isothermal titration microcalorimeteren_US
dc.typeinfo:eu-repo/semantics/Articlees
dc.typeArticlees
dc.identifier.doi10.1007/s10973-005-0727-1
dc.identifier.scopus21244482465-
dc.identifier.isi000230670000037
dc.contributor.authorscopusid6506079738-
dc.contributor.authorscopusid6603271349-
dc.description.lastpage773-
dc.description.firstpage769-
dc.relation.volume80-
dc.investigacionCienciasen_US
dc.type2Artículoen_US
dc.contributor.daisngid2312735
dc.contributor.daisngid1486637
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:de Rivera, MR
dc.contributor.wosstandardWOS:Socorro, F
dc.date.coverdateJunio 2005
dc.identifier.ulpgces
dc.description.jcr1,425
dc.description.jcrqQ2
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR Termofísica de Líquidos y Calorimetría-
crisitem.author.deptDepartamento de Física-
crisitem.author.deptGIR Termofísica de Líquidos y Calorimetría-
crisitem.author.deptDepartamento de Física-
crisitem.author.orcid0000-0002-6737-4096-
crisitem.author.orcid0000-0002-4890-5947-
crisitem.author.parentorgDepartamento de Física-
crisitem.author.parentorgDepartamento de Física-
crisitem.author.fullNameRodríguez De Rivera Rodríguez, Manuel Jose M.-
crisitem.author.fullNameSocorro Lorenzo, Fabiola Lourdes-
Colección:Artículos
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.