Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/48045
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Hernández‐Brito, J. J. | en_US |
dc.contributor.author | Cardona‐Castellano, P. | en_US |
dc.contributor.author | Pérez‐Peña, J. | en_US |
dc.contributor.author | Gelado‐Caballero, Ma D. | en_US |
dc.date.accessioned | 2018-11-23T18:31:38Z | - |
dc.date.available | 2018-11-23T18:31:38Z | - |
dc.date.issued | 1990 | en_US |
dc.identifier.issn | 1040-0397 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/48045 | - |
dc.description.abstract | A computer‐controlled electrochemical system has been developed to determine heavy metal using stripping voltammetry. The system consists of a potentiostat (which we have designed and developed), a polarographic static mercury electrode (303A, PAR), an analog‐digital conversion board (DT2801‐A), a personal computer, and an HP7440 plotter. The potentiostat runs between −2.0 to +2.0 V with multirange current selection between ±50 nA and ±100 μA. There are various outlet channels with different time constants and noise levels. The fastest channel can detect processes on the order of 200 μs with a noise level of ±2.0 nA, while for 30 ms processes the noise is ±100 pA. The software developed controls the sequences of potentials, acquires and stores the currents, and plots them at its convenience. The system has been tested successfully in the determination of different metals using anodic and cathodic stripping voltammetry with different types of waveforms. | en_US |
dc.language | eng | en_US |
dc.publisher | 1040-0397 | - |
dc.relation.ispartof | Electroanalysis | en_US |
dc.source | Electroanalysis [ISSN 1040-0397], v. 2, p. 401-408 | en_US |
dc.subject | 230331 Química del agua | en_US |
dc.subject.other | Electroanalysis | en_US |
dc.subject.other | Stripping voltammetry | en_US |
dc.title | Development of a computerized electrochemical system for stripping voltammetry | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1002/elan.1140020512 | |
dc.identifier.scopus | 84987453402 | - |
dc.contributor.authorscopusid | 35614212100 | - |
dc.contributor.authorscopusid | 15749025600 | - |
dc.contributor.authorscopusid | 7004839316 | - |
dc.contributor.authorscopusid | 6506058559 | - |
dc.description.lastpage | 408 | - |
dc.description.firstpage | 401 | - |
dc.relation.volume | 2 | - |
dc.investigacion | Ciencias | en_US |
dc.type2 | Artículo | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Enero 1990 | |
dc.identifier.ulpgc | Sí | es |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR Tecnologías, Gestión y Biogeoquímica Ambiental | - |
crisitem.author.dept | GIR IUNAT: Fotocatálisis y espectroscopía para aplicaciones medioambientales. | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | GIR Tecnologías, Gestión y Biogeoquímica Ambiental | - |
crisitem.author.dept | Departamento de Química | - |
crisitem.author.orcid | 0000-0002-5305-1667 | - |
crisitem.author.orcid | 0000-0003-1889-2281 | - |
crisitem.author.orcid | 0000-0003-4001-9673 | - |
crisitem.author.parentorg | Departamento de Química | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.parentorg | Departamento de Química | - |
crisitem.author.fullName | Hernández Brito, José Joaquín | - |
crisitem.author.fullName | Pérez Peña,Jesús | - |
crisitem.author.fullName | Gelado Caballero, María Dolores | - |
Colección: | Artículos |
Citas SCOPUSTM
9
actualizado el 24-nov-2024
Citas de WEB OF SCIENCETM
Citations
8
actualizado el 24-nov-2024
Visitas
88
actualizado el 01-jun-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.