Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/47824
Campo DC Valoridioma
dc.contributor.authorMareci, D.en_US
dc.contributor.authorLucero, V.en_US
dc.contributor.authorMirza Rosca, Julia Claudiaen_US
dc.date.accessioned2018-11-23T16:43:54Z-
dc.date.available2018-11-23T16:43:54Z-
dc.date.issued2009en_US
dc.identifier.issn0034-8570en_US
dc.identifier.otherWoS-
dc.identifier.urihttp://hdl.handle.net/10553/47824-
dc.description.abstractThe electrochemical behaviour of Ti6A14V, TioA13.5Fe and Ti5A12.5Fe alloys has been evaluated in Ringer's solution at 25 °C. The effect of the substitution of vanadium in Ti6A14V alloy has been specifically addressed. The evaluation of the corrosion resistance was carried out through the analysis of the open circuit potential variation with time, potentiodynamic polarization curves, and electrochemical impedance spectroscopy (EIS) tests. Very low current densities were obtained (order of nA/cm2) from the polarization curves and EIS, indicating a typical passive behaviour for all investigated alloys. The EIS results exhibited relative capacitive behaviour (large corrosion resistance) with phase angle close to -80° and relative high impedance values (order of 105 Ω·cm2) at low and medium frequencies, which are indicative of the formation of a highly stable film on these alloys in Ringer's solution. In conclusion, the electrochemical behaviour of Ti6A14V is not affected by the substitution of vanadium with iron.en_US
dc.description.abstractEl comportamiento electroquímico de las aleaciones Ti6Al4V, Ti6Al3.5Fe y Ti5Al2.5Fe fue evaluado en una disolución Ringer a 25 °C. Se ha estudiado especialmente el efecto de la sustitución del vanadio en la aleación Ti6Al4V. La evaluación de la resistencia a la corrosión se ha llevado a cabo a través del análisis de la variación del potencial de un circuito abierto con el tiempo, las curvas de polarización potenciodinámicas y los ensayos de espectroscopía de impedancia electroquímica (EIS). Se han obtenido densidades de corriente muy bajas (del orden de nA/cm2) en las curvas de polarización y EIS, indicando un comportamiento pasivo típico para todas las aleaciones investigadas. Los resultados de la EIS mostraron un comportamiento capacitivo relativo (gran resistencia a la corrosión) con ángulos de fase próximos a –80° y valores de impedancia relativamente altos (del orden de 105 Ω·cm2) a frecuencias bajas e intermedias, lo cual es indicativo de la formación de una película altamente estable sobre estas aleaciones en solución Ringer. En resumen, el comportamiento electroquímico de Ti6Al4V no se ve afectado si se sustituye el vanadio por el hierro.en_US
dc.languageengen_US
dc.publisher0034-8570-
dc.relation.ispartofRevista de Metalurgiaen_US
dc.sourceRevista de Metalurgia (Madrid) [ISSN 0034-8570], v. 45, p. 32-41en_US
dc.subject330309 Operaciones electroquímicasen_US
dc.subject3312 Tecnología de materialesen_US
dc.subject3313 Tecnología e ingeniería mecánicasen_US
dc.subject331402 Prótesisen_US
dc.subject.otherCorrosion behavioren_US
dc.subject.otherOrthopedic implantsen_US
dc.subject.otherTi-6Al-4Ven_US
dc.subject.otherFilmsen_US
dc.subject.otherTitaniumen_US
dc.subject.otherAlloysen_US
dc.subject.otherBiocompatibilityen_US
dc.subject.otherCorrosionen_US
dc.subject.otherPolarizationen_US
dc.subject.otherImpedanceen_US
dc.titleEffect of replacement of vanadium by iron on the electrochemical behaviour of titanium alloys in simulated physiological mediaen_US
dc.title.alternativeEfecto de la susti tución de vanadio por hierro en el compor tamiento electroquímico de aleciones de titanio en un medio fisiológico simuladoen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.3989/revmetalm.0750en_US
dc.identifier.scopus67649170512-
dc.identifier.isi000264937500004-
dc.contributor.authorscopusid24071462300-
dc.contributor.authorscopusid26655899900-
dc.contributor.authorscopusid57197224180-
dc.description.lastpage41en_US
dc.identifier.issue1-
dc.description.firstpage32en_US
dc.relation.volume45en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.contributor.daisngid333355-
dc.contributor.daisngid13309508-
dc.contributor.daisngid2432708-
dc.description.numberofpages10en_US
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Mareci, D-
dc.contributor.wosstandardWOS:Lucero, V-
dc.contributor.wosstandardWOS:Mirza, J-
dc.date.coverdateEnero 2009en_US
dc.identifier.ulpgces
dc.description.jcr0,261
dc.description.jcrqQ3
dc.description.sellofecytSello FECYT
dc.description.scieSCIE
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptGIR Nanomaterials and Corrosion-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.orcid0000-0003-0623-3318-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.fullNameMirza Rosca, Julia Claudia-
Colección:Artículos
miniatura
Effect_replacement
Adobe PDF (1,93 MB)
Vista resumida

Citas SCOPUSTM   

4
actualizado el 21-abr-2024

Citas de WEB OF SCIENCETM
Citations

3
actualizado el 25-feb-2024

Visitas

95
actualizado el 13-ene-2024

Descargas

32
actualizado el 13-ene-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.