Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/47468
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Martín-Fernández, Marcos | en_US |
dc.contributor.author | Alberola-López, Carlos | en_US |
dc.contributor.author | Guerrero-Rodríguez, David | en_US |
dc.contributor.author | Ruiz-Alzola, Juan | en_US |
dc.date.accessioned | 2018-11-23T13:48:01Z | - |
dc.date.available | 2018-11-23T13:48:01Z | - |
dc.date.issued | 2000 | en_US |
dc.identifier.issn | 0277-786X | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/47468 | - |
dc.description.abstract | A novel lossless coding scheme for medical images that allows the final user to switch between a lossy and a lossless mode is proposed. The coder is currently trained for hand-radiographs and fetal electrographies. | en_US |
dc.language | eng | en_US |
dc.publisher | 0277-786X | - |
dc.relation.ispartof | Proceedings of SPIE - The International Society for Optical Engineering | en_US |
dc.source | Proceedings of SPIE - The International Society for Optical Engineering[ISSN 0277-786X],v. 4115, p. 171-181 | en_US |
dc.subject | 3314 Tecnología médica | en_US |
dc.subject.other | Image compression | en_US |
dc.subject.other | Signal to noise ratio | en_US |
dc.subject.other | Quantization | en_US |
dc.subject.other | Radiography | en_US |
dc.subject.other | Medical imaging | en_US |
dc.subject.other | Distortion | en_US |
dc.subject.other | Image quality | en_US |
dc.title | Coding technique with progressive reconstruction based on VQ and entropy coding applied to medical images | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1117/12.411600 | en_US |
dc.identifier.scopus | 0034459125 | - |
dc.contributor.authorscopusid | 57206148356 | - |
dc.contributor.authorscopusid | 57206148356 | - |
dc.contributor.authorscopusid | 55999734500 | - |
dc.contributor.authorscopusid | 6504750954 | - |
dc.contributor.authorscopusid | 56614041800 | - |
dc.description.lastpage | 181 | en_US |
dc.description.firstpage | 171 | en_US |
dc.relation.volume | 4115 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Enero 2000 | en_US |
dc.identifier.ulpgc | Sí | es |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.orcid | 0000-0002-3545-2328 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Ruiz Alzola, Juan Bautista | - |
Appears in Collections: | Artículos |
Page view(s)
72
checked on Jul 27, 2024
Download(s)
101
checked on Jul 27, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.