Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/47464
Campo DC Valoridioma
dc.contributor.authorAlmeida, R. C.en_US
dc.contributor.authorRuiz-Alzola, J.en_US
dc.contributor.authorKikinis, R.en_US
dc.contributor.authorWarfield, S. K.en_US
dc.date.accessioned2018-11-23T13:46:15Z-
dc.date.available2018-11-23T13:46:15Z-
dc.date.issued2001en_US
dc.identifier.issn0277-786Xen_US
dc.identifier.urihttp://hdl.handle.net/10553/47464-
dc.description.abstractA statistical classification algorithm, for MRI segmentation, based on the k Nearest Neighbor rule (kNN) has been implemented with Message Passing Interface (MPI) by partitioning the dataset into similar sized subvolumes and delivering each part to one processor inside a cluster. We have tested the algorithm in two different CPU architectures (SPARC and Intel) and four different configurations including a Beowulf cluster, two Sun clusters and a symmetric multiprocessor. The experiments provide a good speedup in all the cases and show a very good performance/price ratio in the PC-Linux cluster. We present results using a three channel, high resolution original dataset in times less than two minutes in the best cases and we use the segmented maps to make clinically relevant 3D visualizations in interactive times.en_US
dc.languageengen_US
dc.publisher0277-786X-
dc.relation.ispartofProceedings of SPIE - The International Society for Optical Engineeringen_US
dc.sourceProceedings of SPIE - The International Society for Optical Engineering[ISSN 0277-786X],v. 4319, p. 88-91en_US
dc.subject3314 Tecnología médicaen_US
dc.subject.otherImage segmentationen_US
dc.subject.otherMedical imagingen_US
dc.subject.otherMagnetic resonance imagingen_US
dc.subject.other3D modelingen_US
dc.subject.otherBrainen_US
dc.subject.otherPrototypingen_US
dc.titleMedical image segmentation using high performance computer clustersen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.relation.conferenceMedical Imaging 2001 Conference-
dc.identifier.doi10.1117/12.428041en_US
dc.identifier.scopus0034874538-
dc.identifier.isi000171468900012-
dc.contributor.authorscopusid36813568500-
dc.contributor.authorscopusid56614041800-
dc.contributor.authorscopusid7101859155-
dc.contributor.authorscopusid7101859155-
dc.contributor.authorscopusid7005171959-
dc.description.lastpage91en_US
dc.description.firstpage88en_US
dc.relation.volume4319en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.contributor.daisngid2066587-
dc.contributor.daisngid920778-
dc.contributor.daisngid13443-
dc.contributor.daisngid38669-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Almeida, RC-
dc.contributor.wosstandardWOS:Ruiz-Alzola, J-
dc.contributor.wosstandardWOS:Kikinis, R-
dc.contributor.wosstandardWOS:Warfield, SK-
dc.date.coverdateEnero 2001en_US
dc.identifier.conferenceidevents120306-
dc.identifier.ulpgces
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR IUIBS: Tecnología Médica y Audiovisual-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Señales y Comunicaciones-
crisitem.author.orcid0000-0002-3545-2328-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameRuiz Alzola, Juan Bautista-
crisitem.event.eventsstartdate18-02-2001-
crisitem.event.eventsenddate22-02-2001-
Colección:Artículos
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.