Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/47359
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Losa-Reyna, José | - |
dc.contributor.author | Torres-Peralta, Rafael | - |
dc.contributor.author | González Henriquez, Juan José | - |
dc.contributor.author | Calbet, José A.L. | - |
dc.date.accessioned | 2018-11-23T12:55:52Z | - |
dc.date.available | 2018-11-23T12:55:52Z | - |
dc.date.issued | 2015 | - |
dc.identifier.issn | 2051-817X | - |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/47359 | - |
dc.description.abstract | Negative arterial to end-tidal PCO2 differences ((a-ET)PCO2) have been reported in normoxia. To determine the influence of blood temperature on (a-ET)PCO2, 11 volunteers (21 ± 2 years) performed incremental exercise to exhaustion in normoxia (Nx, PIO2: 143 mmHg) and hypoxia (Hyp, PIO2: 73 mmHg), while arterial blood gases and temperature (ABT) were simultaneously measured together with end-tidal PCO2 (PETCO2). After accounting for blood temperature, the (a-ET) PCO2 was reduced (in absolute values) from -4.2 ± 1.6 to -1.1 ± 1.5 mmHg in normoxia and from -1.7 ± 1.6 to 0.9 ± 0.9 mmHg in hypoxia (both P < 0.05). The temperature corrected (a-ET)PCO2 was linearly related with absolute and relative exercise intensity, VO2, VCO2, and respiratory rate (RR) in normoxia and hypoxia (R2: 0.52- 0.59). Exercise CO2 production and PETCO2 values were lower in hypoxia than normoxia, likely explaining the greater (less negative) (a-ET)PCO2 difference in hypoxia than normoxia (P < 0.05). At near-maximal exercise intensity the (a-ET)PCO2 lies close to 0 mmHg, that is, the mean PaCO2 and the mean PETCO2 are similar. The mean exercise (a-ET)PCO2 difference is closely related to the mean A-aDO2 difference (r = 0.90, P < 0.001), as would be expected if similar mechanisms perturb the gas exchange of O2 and CO2 during exercise. In summary, most of the negative (a-ET)PCO2 values observed in previous studies are due to lack of correction of PaCO2 for blood temperature. The absolute magnitude of the (a-ET)PCO2 difference is lower during exercise in hypoxia than normoxia. | - |
dc.language | eng | - |
dc.relation.ispartof | Physiological Reports | - |
dc.source | Physiological Reports, [ISSN: 2051-817X] v. 3 (10). e12512 | - |
dc.subject | 241106 Fisiología del ejercicio | - |
dc.subject.other | Blood temperature | - |
dc.subject.other | Gas exchange | - |
dc.subject.other | Gradient | - |
dc.subject.other | Hypoxia | - |
dc.subject.other | PCO2 | - |
dc.title | Arterial to end‐tidal Pco2 difference during exercise in normoxia and severe acute hypoxia: importance of blood temperature correction | - |
dc.type | info:eu-repo/semantics/Article | - |
dc.type | Article | - |
dc.identifier.doi | 10.14814/phy2.12512 | - |
dc.identifier.scopus | 84992343996 | - |
dc.identifier.isi | 000214794800021 | - |
dc.contributor.authorscopusid | 56297981500 | - |
dc.contributor.authorscopusid | 56431163500 | - |
dc.contributor.authorscopusid | 6508312288 | - |
dc.contributor.authorscopusid | 7004323423 | - |
dc.identifier.issue | 10 | - |
dc.relation.volume | 3 | - |
dc.investigacion | Ciencias | - |
dc.type2 | Artículo | - |
dc.contributor.daisngid | 4486976 | - |
dc.contributor.daisngid | 4392482 | - |
dc.contributor.daisngid | 2563867 | - |
dc.contributor.daisngid | 90295 | - |
dc.description.numberofpages | 9 | - |
dc.utils.revision | Sí | - |
dc.contributor.wosstandard | WOS:Losa-Reyna, J | - |
dc.contributor.wosstandard | WOS:Torres-Peralta, R | - |
dc.contributor.wosstandard | WOS:Henriquez, JJG | - |
dc.contributor.wosstandard | WOS:Calbet, JAL | - |
dc.date.coverdate | Enero 2015 | - |
dc.identifier.ulpgc | Sí | es |
dc.description.esci | ESCI | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR IUIBS: Rendimiento humano, ejercicio físico y salud | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | GIR IUIBS: Rendimiento humano, ejercicio físico y salud | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Matemáticas | - |
crisitem.author.dept | GIR IUIBS: Rendimiento humano, ejercicio físico y salud | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Educación Física | - |
crisitem.author.orcid | 0000-0002-0848-4260 | - |
crisitem.author.orcid | 0000-0002-0622-5580 | - |
crisitem.author.orcid | 0000-0002-9215-6234 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Sanchez De Torres Peralta,Rafael | - |
crisitem.author.fullName | González Henríquez, Juan José | - |
crisitem.author.fullName | López Calbet, José Antonio | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.