Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/47198
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Afonso, A. M. | en_US |
dc.contributor.author | Santana, J. J. | en_US |
dc.contributor.author | Montelongo, F. Garcia | en_US |
dc.date.accessioned | 2018-11-23T11:36:35Z | - |
dc.date.available | 2018-11-23T11:36:35Z | - |
dc.date.issued | 1986 | en_US |
dc.identifier.issn | 0039-9140 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/47198 | - |
dc.description.abstract | A kinetic fluorimetric method for the determination of silver is described, based on its catalytic effect on the oxidation of pyrocatechol-1-aldehyde 2-pyridylhydrazone by peroxodisulphate. In aqueous solution silver concentrations of 0.2–0.8 can be determined, and 10–80 in the presence of 1,10-phenanthroline as activator. The fluorescent species obtained (λex 357 nm, λem 445 nm) results from oxidation of the reagent. The kinetic parameters and the interferences are reported, and the method is applied to the determination of silver in developed panchromatic plates. | en_US |
dc.language | eng | en_US |
dc.publisher | 0039-9140 | - |
dc.relation.ispartof | Talanta | en_US |
dc.source | Talanta [ISSN 0039-9140], v. 33, p. 779-783 | en_US |
dc.subject | 2301 química analítica | en_US |
dc.subject.other | Spectrofluorimetry | en_US |
dc.subject.other | Silver determination | en_US |
dc.title | Kinetic spectrofluorimetric determination of silver, based on its catalytic effect on the oxidation of pyrocatechol-1-aldehyde 2-pyridylhydrazone by peroxodisulphate in the presence of 1,10-phenanthroline as activator | en_US |
dc.type | info:eu-repo/semantics/article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1016/0039-9140(86)80193-X | en_US |
dc.identifier.scopus | 0345077816 | - |
dc.contributor.authorscopusid | 7006044068 | - |
dc.contributor.authorscopusid | 56248783900 | - |
dc.contributor.authorscopusid | 6603039854 | - |
dc.description.lastpage | 783 | - |
dc.description.firstpage | 779 | - |
dc.relation.volume | 33 | - |
dc.investigacion | Ciencias | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.ulpgc | Sí | es |
dc.description.scie | SCIE | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR IUNAT: Análisis Químico Medioambiental | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Química | - |
crisitem.author.orcid | 0000-0002-5635-7215 | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.fullName | Santana Rodríguez, José Juan | - |
Colección: | Artículos |
Citas SCOPUSTM
7
actualizado el 02-mar-2025
Citas de WEB OF SCIENCETM
Citations
6
actualizado el 02-mar-2025
Visitas
115
actualizado el 01-nov-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.