Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/47188
Campo DC Valoridioma
dc.contributor.authorMartín-Lázaro, A. Bermejoen_US
dc.contributor.authorHernández García, J.en_US
dc.contributor.authorSantana Rodríguez, José Juanen_US
dc.date.accessioned2018-11-23T11:31:48Z-
dc.date.available2018-11-23T11:31:48Z-
dc.date.issued1992en_US
dc.identifier.issn0937-0633en_US
dc.identifier.urihttp://hdl.handle.net/10553/47188-
dc.description.abstractPerylene and benzo[g,h,i]perylene have been studied in the presence of several surfactants. A synchronous spectrofluorimetric method has been developed for simultaneous determination of perylene and benzo[g,h,i]perylene in a hexadecyltrimethylammonium bromide (HDTAB) micellar medium, with detection limits of 0.12 and 0.21 ng/ml for perylene and benzo[g,h,i]perylene, respectively. The method has been applied to the determination of both hydrocarbons added to sea water with acceptable results.en_US
dc.languageengen_US
dc.publisher0937-0633-
dc.relation.ispartofFresenius' Journal of Analytical Chemistryen_US
dc.sourceFresenius' Journal of Analytical Chemistry [ISSN 0937-0633], v. 343 (6), p. 509-512en_US
dc.subject2301 química analíticaen_US
dc.subject.otherPhysical Chemistryen_US
dc.subject.otherSurfactanten_US
dc.subject.otherAnalytical Chemistryen_US
dc.subject.otherInorganic Chemistryen_US
dc.subject.otherBromideen_US
dc.titleSimultaneous determination of perylene and benzo [g,h,i] perylene by synchronous fluorescence using a micellar systemen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1007/BF00322159
dc.identifier.scopus33749369097-
dc.identifier.isiA1992JA74100009
dc.contributor.authorscopusid8934039000-
dc.contributor.authorscopusid56423923700-
dc.contributor.authorscopusid56248783900-
dc.description.lastpage512-
dc.description.firstpage509-
dc.relation.volume343-
dc.investigacionCienciasen_US
dc.type2Artículoen_US
dc.contributor.daisngid8651652
dc.contributor.daisngid3972119
dc.contributor.daisngid30342984
dc.contributor.wosstandardWOS:MARTINLAZARO, AB
dc.contributor.wosstandardWOS:GARCIA, JH
dc.contributor.wosstandardWOS:RODRIGUEZ, JJS
dc.date.coverdateJunio 1992
dc.identifier.ulpgces
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR IUNAT: Análisis Químico Medioambiental-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Química-
crisitem.author.orcid0000-0002-5635-7215-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.fullNameSantana Rodríguez, José Juan-
Colección:Artículos
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.